Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.04.2026. Verfasst von Vidhyadhar D und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics Crown and Bridge, Balaji Family Dental Care, Kamareddy, Telangana, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The persistent presence of a microgap at the implant-abutment interface continues to pose biological and mechanical challenges, yet the influence of different connection designs remains insufficiently understood. Therefore, it is of interest to evaluate 100 implant abutment assemblies external hex, internal hex and internal conical using SEM before and after cyclic loading. External hex connections showed the largest microgaps, internal hex showed moderate values and internal conical exhibited the smallest and most stable interface. Statistical analysis confirmed significant differences among the designs, with conical connections demonstrating superior resistance to microgap enlargement under functional loading. Thus, we show new comparative evidence showing that internal conical connections provide the most stable interface, thereby advancing knowledge on optimal implant-abutment design for improved clinical outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics Crown and Bridge, Balaji Family Dental Care, Kamareddy, Telangana, India.
- Department of Biomedical Sciences, Rutgers Biomedical and Health Sciences, Newark, New Jersey, 07107, USA.
- Department of General Dentistry, Always Smile Dental Care, North Brunswick Township, New Jersey, USA.
- Department of General Dentistry, Indiana University School of Dentistry Indianapolis, Indiana, USA.
- Department of Prosthodontics, Panineeya Institute of Dental Sciences, Hyderabad, Telangana, India.
- Department of Prosthodontics, MNR Dental College and Hospital, Sangareddy, Telangana, India.
Zitieren
APA
D, V., Pavuluri, T. C., Anne, V., Katamneni, S., Bharathi, B. V., Chiluka, R., & Pudi, S. (2026). Evaluation of microgap at implant abutment interface using different connection design. Bioinformation, 22(4), 2283-2286. https://doi.org/10.6026/973206300222283
Vancouver
D V, Pavuluri TC, Anne V, Katamneni S, Bharathi BV, Chiluka R, et al. Evaluation of microgap at implant abutment interface using different connection design. Bioinformation. 2026;22(4):2283-2286. doi:10.6026/973206300222283
BibTeX
@article{D2026,
author = {D, Vidhyadhar and Pavuluri, Tejosmita Chowdary and Anne, Vivek and Katamneni, Sruthi and Bharathi, B Vimal and Chiluka, Radha and Pudi, Sriharsha},
title = {Evaluation of microgap at implant abutment interface using different connection design},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {4},
pages = {2283--2286},
doi = {10.6026/973206300222283}
}
EUVIMED