Assessment of Large Animal Vascular Dimensions for Intra-Aortic Device Research and Development: A Systematic Review
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2023
DOI: 10.1177/15569845231164134 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2023. Verfasst von Gabriel Georges und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Surgery Division, Quebec Heart and Lung Institute, QC, Canada. Hauptthemen laut MEDLINE: Aorta, Angiography. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Animal studies are often required to evaluate new cardiovascular medical devices before they reach the market. Moreover, first-generation novel devices including aortic endovascular prostheses and circulatory support devices are often larger than later iterations or tested in a limited range of sizes. One of the challenges in evaluating these devices is finding a model that is both accessible and anatomically similar to humans, as there is a paucity of data on vascular dimensions in large animals. We set out to complete a comprehensive review of available reports on vascular dimensions in swine, ovine, and bovine models, with a particular focus on the descending aorta and ilio-femoral arteries. We searched Embase and MEDLINE databases for reports of descending aorta and peripheral vascular dimension in large animal models. Data from swine, ovine, and bovine models were separated by weight into 3 categories: 40 to 60 kg, 61 to 80 kg, and >80 kg. We also incorporate our computed tomography angiography data from 4 large sheep and 9 calves into this review. Swine, sheep, and calf >80 kg may serve as the best models to maximize aortic diameter resemblance to humans. If device implantation can be achieved in aortas of smaller dimensions, care should be taken to ensure access site suitability such as the common femoral artery in these smaller animals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Surgery Division, Quebec Heart and Lung Institute, QC, Canada.
- General Surgery Division, Laval University Hospital Center, Quebec, QC, Canada.
ORCID-Profile: Gabriel Georges
Zitieren
APA
Georges, G., Couture, T., & Voisine, P. (2023). Assessment of Large Animal Vascular Dimensions for Intra-Aortic Device Research and Development: A Systematic Review. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845231164134
Vancouver
Georges G, Couture T, Voisine P. Assessment of Large Animal Vascular Dimensions for Intra-Aortic Device Research and Development: A Systematic Review. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2023. doi:10.1177/15569845231164134
BibTeX
@article{Georges2023,
author = {Georges, Gabriel and Couture, Thomas and Voisine, Pierre},
title = {Assessment of Large Animal Vascular Dimensions for Intra-Aortic Device Research and Development: A Systematic Review},
journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
year = {2023},
doi = {10.1177/15569845231164134}
}
EUVIMED