EUVIMEDEUVIMED entdecken
Crossref

Evaluation of different indices to measure elastic properties of the aorta in a pulsatile mock circulation loop

Jeremy Jarman, Daniel Navarro, Johanna Ticar, Giulia Tosto, Matthias Dittrich, David Santer, Judith Radloff, Bruno Mora, Michael Moore, Martin Czerny, Roman Gottardi iD

European Journal of Cardio-Thoracic Surgery · 2025

DOI: 10.1093/ejcts/ezaf073 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2025. Verfasst von Jeremy Jarman und 10 weiteren Autor:innen. Beteiligte Einrichtung: Ascense Medical GmbH, Vienna, Austria. Hauptthemen laut MEDLINE: Pulsatile Flow, Aorta, Thoracic, Vascular Stiffness, Models, Cardiovascular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES The aim of this study was to investigate how different indices to express aortic stiffness can be understood and what the impact of different loading conditions is. METHODS Thoracic aortas from swine (n = 6) and sheep (n = 6) were tested in a pulsatile mock circulation loop. Aortas were loaded at constant heart rate and stroke volume at increasing diastolic pressure with a constant pulse pressure of 40 mmHg from 60/20 to 180/140 mmHg in 20 mmHg steps. Data were analysed using commonly used formulas to calculate absolute strain, dynamic strain, circumferential strain, compliance, distensibility, pulse wave velocity, elastic modulus, Young’s modulus, Peterson’s elastic modulus, non-logarithmic and logarithmic stiffness index. RESULTS Ovine samples had a smaller diastolic diameter at 60/20 mmHg compared to porcine samples (15.9 ± 0.6 vs 17.9 ± 0.7 mm) but a larger systolic and diastolic diameter at pressure of 180/140 mmHg (27.8 ± 1.5 vs 24.6 ± 0.7 and 26.6 ± 1.6 vs 23.9 ± 0.7 mm) indicating a higher aortic elasticity of ovine samples. An increase in pressure resulted in a stiffening of all samples with a significant difference in all included formulas (all P < 0.001). In the normotensive pressure range (100/60 to 140/100 mmHg), only non-logarithmic stiffness index in porcine samples showed no significant difference (P = 0.251), all other formulas showed a significant difference (P < 0.05). CONCLUSIONS In this experimental setup, we could show that aortic elasticity is highly dependent on blood pressure. None of the formulas currently used provides a consistent value over the tested pressure range. A formula that can give a consistent value for aortic stiffness would be highly desirable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulsatile FlowAorta, ThoracicVascular StiffnessModels, CardiovascularAortaAnimalsSheepSwineElasticityBlood PressureElastic ModulusPulse Wave Analysis

Stichwörter der Autor:innen

AortaAortic StiffnessComplianceDistensibilityPulse Wave Velocity

Autor:innen und Institutionen

  • Ascense Medical GmbH, Vienna, Austria.
  • Center for Biomedical Research and Translational Surgery, Medical University of Vienna, Vienna, Austria.
  • Division of Cardiothoracic and Vascular Anaesthesia and Intensive Care Medicine, Department of Anaesthesiology, General Intensive Care and Pain Medicine, Medical University of Vienna, Vienna, Austria.
  • Department of Cardiovascular Surgery, University Heart Center Freiburg-Bad Krozingen, Freiburg, Germany.
  • Faculty of Medicine, Albert Ludwigs University Freiburg, Freiburg, Germany.

ORCID-Profile: Roman Gottardi

Zitieren

APA

Jarman, J., Navarro, D., Ticar, J., Tosto, G., Dittrich, M., Santer, D., Radloff, J., Mora, B., Moore, M., Czerny, M., & Gottardi, R. (2025). Evaluation of different indices to measure elastic properties of the aorta in a pulsatile mock circulation loop. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezaf073

Vancouver

Jarman J, Navarro D, Ticar J, Tosto G, Dittrich M, Santer D, et al. Evaluation of different indices to measure elastic properties of the aorta in a pulsatile mock circulation loop. European Journal of Cardio-Thoracic Surgery. 2025. doi:10.1093/ejcts/ezaf073

BibTeX
@article{Jarman2025,
  author = {Jarman, Jeremy and Navarro, Daniel and Ticar, Johanna and Tosto, Giulia and Dittrich, Matthias and Santer, David and Radloff, Judith and Mora, Bruno and Moore, Michael and Czerny, Martin and Gottardi, Roman},
  title = {Evaluation of different indices to measure elastic properties of the aorta in a pulsatile mock circulation loop},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2025},
  doi = {10.1093/ejcts/ezaf073}
}
Kostenlos starten →