EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Streamlining Thoracic Radiotherapy Quality assurance: One-Class Classification for Automated OAR Contour Assessment

Yihao Zhao iD, Cuiyun Yuan, Ying Liang, Yang Li iD, Chunxia Li, Man Zhao, Jun Hu, Ningze Zhong, Wei Liu iD, Chenbin Liu iD

Technology in Cancer Research & Treatment · 2025-06 · 24

DOI: 10.1177/15330338251345895 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, online erschienen am 22.05.2025. Verfasst von Yihao Zhao und 9 weiteren Autor:innen. Beteiligte Einrichtung: National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peki…. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Quality Assurance, Health Care, Organs at Risk. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union M…, National Natural Science Foundation of China, Shenzhen High-level Hospital Construction Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Automating quality assurance (QA) for contours generated by automatic algorithms is critical in radiotherapy treatment planning. Manual QA is tedious, time-consuming, and prone to subjective experiences. Automatic segmentation reduces physician workload and improves consistency. However, an effective QA process for these automatic contours remains an unmet need in clinical practice. Materials and Methods The patient data used in this study was derived from the AAPM Thoracic Auto-Segmentation Challenge dataset, including left and right lungs, heart, esophagus, and spinal cord. Two groups of organ-at-risk (OAR) were generated. A ResNet-152 network was used as a feature extractor, and a one-class support vector machine (OC-SVM) was employed to classify contours as ‘high’ or ‘low’ quality. To evaluate the generalizability, we generated low-quality contours using translation and resizing techniques and assessed correlations between detection limits and metrics such as volume, Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), and mean surface distance (MSD).

Results

The proposed OC-SVM model outperformed binary classifiers n metrics such as balanced accuracy and area under the receiver operating characteristic curve (AUC) . It demonstrated superior performance in detecting various types of contour errors while maintaining high interpretability. Strong correlations were observed between detection limits and contour metrics.

Conclusion

Our proposed model integrates an attention mechanism with a one-class classification framework to automate QA for OAR delineations. This approach effectively detects diverse types of contour errors with high accuracy, significantly reducing the burden on physicians during radiotherapy planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedQuality Assurance, Health CareOrgans at RiskHumansSupport Vector MachineAlgorithms

Stichwörter der Autor:innen

contour delineation.one class classificationquality assuranceradiotherapy

Autor:innen und Institutionen

  • National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, Guangdong, China.
  • School of Electronics and Communication Engineering, Sun Yat-sen University, Shenzhen, Guangdong, China.
  • Faculty of Health Sciences, University of Macau, Macau, China.
  • Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA.

ORCID-Profile: Yihao Zhao, Yang Li, Wei Liu, Chenbin Liu

Förderung

  • National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union M…
  • National Natural Science Foundation of China
  • Shenzhen High-level Hospital Construction Fund
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • Shenzhen High-level Hospital Construction Fund, Shenzhen Key Medical Discipline Construction Fund
  • Sanming Project of Medicine in Shenzen Municipality
  • Natural Science Foundation of Shenzhen Municipality

Zitieren

APA

Zhao, Y., Yuan, C., Liang, Y., Li, Y., Li, C., Zhao, M., Hu, J., Zhong, N., Liu, W., & Liu, C. (2025). Streamlining Thoracic Radiotherapy Quality assurance: One-Class Classification for Automated OAR Contour Assessment. Technology in Cancer Research & Treatment, 24. https://doi.org/10.1177/15330338251345895

Vancouver

Zhao Y, Yuan C, Liang Y, Li Y, Li C, Zhao M, et al. Streamlining Thoracic Radiotherapy Quality assurance: One-Class Classification for Automated OAR Contour Assessment. Technology in Cancer Research & Treatment. 2025;24. doi:10.1177/15330338251345895

BibTeX
@article{Zhao2025,
  author = {Zhao, Yihao and Yuan, Cuiyun and Liang, Ying and Li, Yang and Li, Chunxia and Zhao, Man and Hu, Jun and Zhong, Ningze and Liu, Wei and Liu, Chenbin},
  title = {Streamlining Thoracic Radiotherapy Quality assurance: One-Class Classification for Automated OAR Contour Assessment},
  journal = {Technology in Cancer Research & Treatment},
  year = {2025},
  volume = {24},
  doi = {10.1177/15330338251345895}
}
Kostenlos starten →