Effect of the Residual Errors on the Dose for Left-Sided Breast Cancer Radiotherapy After Translation Error Correction Based on CBCT
Technology in Cancer Research & Treatment · 2025
DOI: 10.1177/15330338251338489 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, 2025. Verfasst von Ya Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Radiotherapy Physics and Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Cone-Beam Computed Tomography, Radiotherapy, Intensity-Modulated, Unilateral Breast Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Science and Technology Department of Sichuan Province of China.
Abstract (Originalsprache)
Objective
This study analyzed the dosimetric impact of residual errors (rotational and deformation errors) in left-sided breast cancer radiotherapy after cone-beam CT (CBCT)-based translational errors correction.
Methods
Twenty patients treated with intensity-modulated radiotherapy (IMRT) were retrospectively analyzed. Virtual CT images were generated by deforming and registering CBCT images with planning CT images. The accumulated dose was calculated to assess residual errors effects on target and organs at risk (OARs). A phantom test was conducted to evaluate rotational errors impacts.
Results
Results showed significant dose differences: for 4005 cGy, D98 and D95 of the breast (PTV b ) decreased, and mean dose, V30, and V20 of the left lung reduced; for 5000 cGy, D98 of the supraclavicular lymph nodes (PTV sc ) and PTVb, D95 of PTV b , and mean dose and V20 of the heart differed significantly. Phantom simulations revealed that pitch angles ≤−1.8° and roll/yaw angles >2° caused overdosing in the left lung and heart, with maximum dose differences of 31.89% (heart) and 19.19% (lung) for 4005 cGy, and 26.32% (heart) and 20.92% (PTV sc ) for 5000 cGy.
Conclusion
Residual errors significantly affect dose distribution despite CBCT-based translational correction. Improved immobilization techniques or 6DOF couch correction are recommended to mitigate rotational errors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiotherapy Physics and Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, China.
ORCID-Profile: Ya Wang, Lu Zeng, Pan Gong, Denghong Liu, Qianqian Meng, Konglong Shen, Zhihui Liu, Renming Zhong
Förderung
- Science and Technology Department of Sichuan Province of China
Zitieren
APA
Wang, Y., Zeng, L., Gong, P., Liu, D., Meng, Q., Shen, K., Liu, Z., & Zhong, R. (2025). Effect of the Residual Errors on the Dose for Left-Sided Breast Cancer Radiotherapy After Translation Error Correction Based on CBCT. Technology in Cancer Research & Treatment. https://doi.org/10.1177/15330338251338489
Vancouver
Wang Y, Zeng L, Gong P, Liu D, Meng Q, Shen K, et al. Effect of the Residual Errors on the Dose for Left-Sided Breast Cancer Radiotherapy After Translation Error Correction Based on CBCT. Technology in Cancer Research & Treatment. 2025. doi:10.1177/15330338251338489
BibTeX
@article{Wang2025,
author = {Wang, Ya and Zeng, Lu and Gong, Pan and Liu, Denghong and Meng, Qianqian and Shen, Konglong and Liu, Zhihui and Zhong, Renming},
title = {Effect of the Residual Errors on the Dose for Left-Sided Breast Cancer Radiotherapy After Translation Error Correction Based on CBCT},
journal = {Technology in Cancer Research & Treatment},
year = {2025},
doi = {10.1177/15330338251338489}
}
EUVIMED