Non‐coplanar CBCT image reconstruction using a generative adversarial network for non‐coplanar radiotherapy
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14487 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Ran Wei und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sci…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Phantoms, Imaging, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Beijing Hope Run Special Fund of Cancer Foundation of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To develop a non‐coplanar cone‐beam computed tomography (CBCT) image reconstruction method using projections within a limited angle range for non‐coplanar radiotherapy.
Methods
A generative adversarial network (GAN) was utilized to reconstruct non‐coplanar CBCT images. Data from 40 patients with brain tumors and two head phantoms were used in this study. In the training stage, the generator of the GAN used coplanar CBCT and non‐coplanar projections as the input, and an encoder with a dual‐branch structure was utilized to extract features from the coplanar CBCT and non‐coplanar projections separately. Non‐coplanar CBCT images were then reconstructed using a decoder by combining the extracted features. To improve the reconstruction accuracy of the image details, the generator was adversarially trained using a patch‐based convolutional neural network as the discriminator. A newly designed joint loss was used to improve the global structure consistency rather than the conventional GAN loss. The proposed model was evaluated using data from eight patients and two phantoms at four couch angles (±45°, ±90°) that are most commonly used for brain non‐coplanar radiotherapy in our department. The reconstructed accuracy was evaluated by calculating the root mean square error (RMSE) and an overall registration error ε , computed by integrating the rigid transformation parameters.
Results
In both patient data and phantom data studies, the qualitative and quantitative metrics results indicated that ± 45° couch angle models performed better than ±90° couch angle models and had statistical differences. In the patient data study, the mean RMSE and ε values of couch angle at 45°, −45°, 90°, and −90° were 58.5 HU and 0.42 mm, 56.8 HU and 0.41 mm, 73.6 HU and 0.48 mm, and 65.3 HU and 0.46 mm, respectively. In the phantom data study, the mean RMSE and ε values of couch angle at 45°, −45°, 90°, and −90° were 91.2 HU and 0.46 mm, 95.0 HU and 0.45 mm, 114.6 HU and 0.58 mm, and 102.9 HU and 0.52 mm, respectively.
Conclusions
The results show that the reconstructed non‐coplanar CBCT images can potentially enable intra‐treatment three‐dimensional position verification for non‐coplanar radiotherapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
ORCID-Profile: Zhiyue Song
Förderung
- National Key Research and Development Program of China
- Beijing Hope Run Special Fund of Cancer Foundation of China
- National Natural Science Foundation of China
- Natural Science Foundation of Beijing, China
Zitieren
APA
Wei, R., Song, Z., Pan, Z., Cao, Y., Song, Y., & Dai, J. (2024). Non‐coplanar CBCT image reconstruction using a generative adversarial network for non‐coplanar radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14487
Vancouver
Wei R, Song Z, Pan Z, Cao Y, Song Y, Dai J. Non‐coplanar CBCT image reconstruction using a generative adversarial network for non‐coplanar radiotherapy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14487
BibTeX
@article{Wei2024,
author = {Wei, Ran and Song, Zhiyue and Pan, Ziqi and Cao, Ying and Song, Yongli and Dai, Jianrong},
title = {Non‐coplanar CBCT image reconstruction using a generative adversarial network for non‐coplanar radiotherapy},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14487}
}
EUVIMED