EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical application of 3D‐printed bolus in postmastectomy radiotherapy

Qianqian Liu, Xuming Chen, Zhekai Hu, Lingtong Hou, Yihang Zhang iD, Tiening Zhang, Shengyu Yao iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70393 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Qianqian Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Breast Neoplasms, Radiotherapy Planning, Computer-Assisted, Mastectomy. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanghai Songjiang Science and Technology Commission, Shanghai Association of Chinese Integrative Medicine, Shanghai Key Laboratory of Molecular Imaging.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the fitting accuracy and dose influence of 3D‐printed bolus (3DPB) during postmastectomy radiotherapy.

Methods

Air gaps were assessed using cone‐beam computed tomography (CBCT) images for 27 breast cancer patients who received postmastectomy radiotherapy. Then a CIRS thoracic phantom was used to evaluate the dosimetric effects of different air gap sizes.

Results

In CBCT images of patients, compared with conventional bolus (CB), 3DPB significantly reduced both the maximum and total air gap volumes by an average between 103.04 cm 3 and 124.63 cm 3 , respectively. The average maximum gap height was 0.53 ± 0.20 cm for 3DPB and 2.23 ± 0.41 cm for CB (p 2 cm, the dose reduction becomes significant, warranting the use of 3D‐printed boluses to ensure adequate target coverage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalBreast NeoplasmsRadiotherapy Planning, Computer-AssistedMastectomyPhantoms, ImagingCone-Beam Computed TomographyHumansFemaleRadiotherapy DosageRadiotherapy, Intensity-ModulatedOrgans at RiskMiddle Aged

Stichwörter der Autor:innen

3D‐printed bolusAir gapPostmastectomyRadiation therapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China.

ORCID-Profile: Yihang Zhang, Shengyu Yao

Förderung

  • Shanghai Songjiang Science and Technology Commission
  • Shanghai Association of Chinese Integrative Medicine
  • Shanghai Key Laboratory of Molecular Imaging

Zitieren

APA

Liu, Q., Chen, X., Hu, Z., Hou, L., Zhang, Y., Zhang, T., & Yao, S. (2025). Clinical application of 3D‐printed bolus in postmastectomy radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70393

Vancouver

Liu Q, Chen X, Hu Z, Hou L, Zhang Y, Zhang T, et al. Clinical application of 3D‐printed bolus in postmastectomy radiotherapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70393

BibTeX
@article{Liu2025,
  author = {Liu, Qianqian and Chen, Xuming and Hu, Zhekai and Hou, Lingtong and Zhang, Yihang and Zhang, Tiening and Yao, Shengyu},
  title = {Clinical application of 3D‐printed bolus in postmastectomy radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70393}
}