EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Multimodal Point Cloud-Based Method for Tumor Localization in Robotic Ultrasound-Guided Radiotherapy

Lintao Song, Qixuan Li iD, Zhang Sai, Kangkang Sun, Wei Chen, Heng Zhang iD, Yibo Wang, Zhuqing Jiao, Xinye Ni iD

Technology in Cancer Research & Treatment · 2024

DOI: 10.1177/15330338241273149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, 2024. Verfasst von Lintao Song und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, The Affiliated Changzhou NO.2 People's Hospital of Nanjing Medical University, Changzhou, China. Hauptthemen laut MEDLINE: Radiotherapy, Image-Guided, Neoplasms, Radiotherapy Planning, Computer-Assisted, Tomography, X-Ray Computed. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Jiangsu Provincial Natural Science Foundation General Project, General Program of National Natural Science Foundation of China, Jiangsu Provincial Key Research and Development Program Social Development Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Part of the tumor localization methods in radiotherapy have poor real-time performance and may generate additional radiation. We propose a multimodal point cloud-based method for tumor localization in robotic ultrasound-guided radiotherapy, which only irradiates computed tomography (CT) during radiotherapy planning to avoid additional radiation.

Methods

The tumor position was determined using the CT point cloud, and the red green blue depth (RGBD) point cloud was used to determine body surface scanning location corresponding to the tumor location. The relationship between the CT point cloud and RGBD point cloud was established through multi-modal point cloud registration. The point cloud was then used for robot tumor localization through coordinate transformation between camera and robot.

Results

The maximum mean absolute error of the tumor location in the X, Y, and Z directions of the robot coordinate system were 0.781, 1.334, and 1.490 mm, respectively. The average point-to-point translation mean absolute error between the actual and predicted positions of the localization points was 1.847 mm. The maximum error in the random positioning experiment was 1.77 mm.

Conclusion

The proposed method is radiation free and has real-time performance, with tumor localization accuracy that meets the requirements of radiotherapy. The proposed method, which potentially reduces the risks associated with radiation exposure while ensuring efficient and accurate tumor localization, represents a promising advancement in the field of radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Image-GuidedNeoplasmsRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansUltrasonographyAlgorithmsPhantoms, ImagingRoboticsRobotic Surgical Procedures

Stichwörter der Autor:innen

multimodal point cloudpoint cloud processingrobotictumor localizationultrasound-guided radiotherapy

Autor:innen und Institutionen

  • Department of Radiotherapy, The Affiliated Changzhou NO.2 People's Hospital of Nanjing Medical University, Changzhou, China.
  • Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, China.
  • Center for Medical Physics, Nanjing Medical University, Changzhou, China.
  • School of Microelectronics and Control Engineering, Changzhou University, Changzhou, China.
  • School of Computer and Artificial Intelligence, Changzhou University, Changzhou, China.

ORCID-Profile: Qixuan Li, Heng Zhang, Xinye Ni

Förderung

  • Jiangsu Provincial Natural Science Foundation General Project
  • General Program of National Natural Science Foundation of China
  • Jiangsu Provincial Key Research and Development Program Social Development Project
  • Jiangsu Provincial Medical Key Discipline (Laboratory) Cultivation Unit
  • Changzhou Social Development Project
  • Jiangsu Provincial Health Commission General Project

Zitieren

APA

Song, L., Li, Q., Sai, Z., Sun, K., Chen, W., Zhang, H., Wang, Y., Jiao, Z., & Ni, X. (2024). A Multimodal Point Cloud-Based Method for Tumor Localization in Robotic Ultrasound-Guided Radiotherapy. Technology in Cancer Research & Treatment. https://doi.org/10.1177/15330338241273149

Vancouver

Song L, Li Q, Sai Z, Sun K, Chen W, Zhang H, et al. A Multimodal Point Cloud-Based Method for Tumor Localization in Robotic Ultrasound-Guided Radiotherapy. Technology in Cancer Research & Treatment. 2024. doi:10.1177/15330338241273149

BibTeX
@article{Song2024,
  author = {Song, Lintao and Li, Qixuan and Sai, Zhang and Sun, Kangkang and Chen, Wei and Zhang, Heng and Wang, Yibo and Jiao, Zhuqing and Ni, Xinye},
  title = {A Multimodal Point Cloud-Based Method for Tumor Localization in Robotic Ultrasound-Guided Radiotherapy},
  journal = {Technology in Cancer Research & Treatment},
  year = {2024},
  doi = {10.1177/15330338241273149}
}
Kostenlos starten →