EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Impact of Respiratory Motion on the Skin Dose for Breast Cancer in Tomotherapy: A Study in the In-house Moving Phantom

Wannapha Nobnop iD, Nattaphol Lertananpipat, Anirut Watcharawipha, Anupong Kongsa, Damrongsak Tippanya, Warit Thongsuk, Imjai Chitapanarux

Technology in Cancer Research & Treatment · 2023

DOI: 10.1177/15330338231197520 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, 2023. Verfasst von Wannapha Nobnop und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiation Oncology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Breast Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Faculty of Medicine, ChiangMai University, CMU Junior Research Fellowship Program, Chiang Mai University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The dose expansion methods as the skin flash and virtual bolus were used to solve intrafraction movement for breast planning due to breathing motion. We investigated the skin dose in each planning method by using optically stimulated luminescence on an in-house moving phantom for breast cancer treatment in tomotherapy. The impact of respiratory motion on skin dose between static and dynamic phantom's conditions was evaluated.

Methods

A phantom was developed with movement controlled by the respirator for generating the respiratory waveforms to simulate respiratory motion. Five optically stimulated luminescence dosimeters were placed on the phantom surface to investigate the skin dose for the TomoDirect and TomoHelical under static and dynamic conditions. Eight treatment plans were generated with and without skin flash or virtual bolus by varying the thickness. The difference in skin dose between the two phantom conditions for each plan was explored.

Results

All plans demonstrated a skin dose of more than 87% of the prescription dose under static conditions. However, the skin dose was reduced to 84.1% (TomoDirect) and 78.9% (TomoHelical) for dynamic conditions. The treatment plans without skin flash or virtual bolus showed significant skin dose differences under static and dynamic conditions by 4.83% (TomoDirect) and 9.43% (TomoHelical), whereas the skin flash with two leaves (TomoDirect 2L) or virtual bolus of at least 1.0 cm thickness (VB1.0) application compensated the skin dose in case of intrafraction movements by presenting a skin dose difference of less than 2% between the static and dynamic conditions.

Conclusion

The skin dose was reduced under dynamic conditions due to breathing motion. The skin flash method with TomoDirect 2L or virtual bolus application with 1.0 cm thickness was useful for maintaining skin dose following the prescription by compensating for intrafraction movement due to respiratory motion for breast cancer in tomotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsRadiotherapy, Intensity-ModulatedFemaleHumansMotionPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

OSLbreast cancermovable phantomskin dosetomotherapy

Autor:innen und Institutionen

  • Division of Radiation Oncology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
  • Northern Thai Research Group of Radiation Oncology (NTRG-RO), Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.

ORCID-Profile: Wannapha Nobnop

Förderung

  • Faculty of Medicine, ChiangMai University
  • CMU Junior Research Fellowship Program, Chiang Mai University

Zitieren

APA

Nobnop, W., Lertananpipat, N., Watcharawipha, A., Kongsa, A., Tippanya, D., Thongsuk, W., & Chitapanarux, I. (2023). Impact of Respiratory Motion on the Skin Dose for Breast Cancer in Tomotherapy: A Study in the In-house Moving Phantom. Technology in Cancer Research & Treatment. https://doi.org/10.1177/15330338231197520

Vancouver

Nobnop W, Lertananpipat N, Watcharawipha A, Kongsa A, Tippanya D, Thongsuk W, et al. Impact of Respiratory Motion on the Skin Dose for Breast Cancer in Tomotherapy: A Study in the In-house Moving Phantom. Technology in Cancer Research & Treatment. 2023. doi:10.1177/15330338231197520

BibTeX
@article{Nobnop2023,
  author = {Nobnop, Wannapha and Lertananpipat, Nattaphol and Watcharawipha, Anirut and Kongsa, Anupong and Tippanya, Damrongsak and Thongsuk, Warit and Chitapanarux, Imjai},
  title = {Impact of Respiratory Motion on the Skin Dose for Breast Cancer in Tomotherapy: A Study in the In-house Moving Phantom},
  journal = {Technology in Cancer Research & Treatment},
  year = {2023},
  doi = {10.1177/15330338231197520}
}
Kostenlos starten →