An alternative to inside-out access for central venous catheter placement in thoracic central vein obstruction
The Journal of Vascular Access · 2026
DOI: 10.1177/11297298261455247 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2026. Verfasst von Anna Maria Ierardi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy. Hauptthemen laut MEDLINE: Catheterization, Central Venous, Radiography, Interventional, Vascular Diseases. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate feasibility, technical success, and safety of a fluoroscopy-guided percutaneous technique for central venous catheter (CVC) placement in patients with thoracic central venous obstruction (TCVO). Materials and methods: We retrospectively included 16 adult and pediatric patients with TCVO requiring CVC placement. Technical success was defined as successful venous access and catheter placement; clinical success as functional catheter use without failure. Safety was assessed using CIRSE classification. Procedural metrics were recorded. Descriptive statistics (median, IQR; counts, %) were used. Exploratory comparisons between obstruction type (Type 1–2B vs 3–4) and procedural metrics were performed using Mann–Whitney U test.
Results
Seventeen procedures were performed in 16 patients (median age 27.5 years, range 7–61; 11 males). Access and catheter placement succeeded in 16/17 procedures (94.1%) and all patients (100%). In one case, first attempt failed and a second successful procedure was requested. First-attempt per-patient technical success was 93.7%. Clinical success was 100%. No major complications occurred; minor adverse events (CIRSE grade 1) were observed in three patients (18.7%). Median procedure time 52 min, fluoroscopy 12 min and 5 s, contrast 46 mL, and DAP 91.3 Gy/cm 2 . Trend toward longer procedure time was noted for Type 3–4 obstructions and collateral snare use.
Conclusion
Fluoroscopy-guided percutaneous CVC placement is feasible and safe in TCVO using the described technique and may represent a widely applicable alternative to dedicated inside-out system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy.
- Department of Oncology and Hemato-Oncology, University of Milan, Milan, Italy.
- Unit of Diagnostic Imaging and Stereotactic Radiosurgery, CDI Centro Diagnostico Italiano S.p.A., Milan, Italy.
ORCID-Profile: Anna Maria Ierardi
Zitieren
APA
Ierardi, A. M., Biondetti, P., Ascenti, V., Angileri, S. A., Torcia, P., Lanza, C., Pellegrino, G., Papa, S., & Carrafiello, G. (2026). An alternative to inside-out access for central venous catheter placement in thoracic central vein obstruction. The Journal of Vascular Access. https://doi.org/10.1177/11297298261455247
Vancouver
Ierardi AM, Biondetti P, Ascenti V, Angileri SA, Torcia P, Lanza C, et al. An alternative to inside-out access for central venous catheter placement in thoracic central vein obstruction. The Journal of Vascular Access. 2026. doi:10.1177/11297298261455247
BibTeX
@article{Ierardi2026,
author = {Ierardi, Anna Maria and Biondetti, Pierpaolo and Ascenti, Velio and Angileri, Salvatore Alessio and Torcia, Pierluca and Lanza, Carolina and Pellegrino, Giuseppe and Papa, Sergio and Carrafiello, Gianpaolo},
title = {An alternative to inside-out access for central venous catheter placement in thoracic central vein obstruction},
journal = {The Journal of Vascular Access},
year = {2026},
doi = {10.1177/11297298261455247}
}