EUVIMEDEUVIMED entdecken
Crossref

Percutaneous CT-Guided Microwave Ablation for the Treatment of Osteoid Osteomas: A Single Center Experience

Ilhan Nahit Mutlu, Mehmet Cingoz, Tevfik Guzelbey, Eda Cingoz, Ozgur Kilickesmez

Academic Radiology · 2024

DOI: 10.1016/j.acra.2024.02.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2024. Verfasst von Ilhan Nahit Mutlu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Basaksehir Cam And Sakura City Hospital, Basaksehir 34480, Istanbul, Turkey. Hauptthemen laut MEDLINE: Microwaves, Osteoma, Osteoid, Tomography, X-Ray Computed, Bone Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: The aim of the current study was to evaluate the feasibility and effectiveness of CT-guided microwave ablation (MWA) in the treatment of osteoid osteomas (OO). MATERIALS AND METHODS: Data from 59 consecutive patients who underwent percutaneous CT-MWA for OO treatment were examined in the current retrospective study. The period of this study spanned from January 2021 to May 2023 at a single institution. The study involved an evaluation of clinical and radiological characteristics, procedural data, Visual Analog Scale (VAS) pain scores, complication incidences, as well as clinical and technical success rates. Statistical analyses were performed by using the Wilcoxon test with Bonferroni correction, Friedman, Spearman, Mann-Whitney U test. RESULTS: 59 patients with an average age of 17.31 ± 8.53 years underwent CT-guided MWA for the treatment of OO. The procedure demonstrated a high success rate, with 96.6% of cases achieving both technical and clinical success. However, recurrence was observed in two patients (3.4%) at the three-month follow-up. These cases were successfully managed with a second MWA procedure. The median VAS pain scores reported by the patients was significantly improved post-procedure: from 8.64 ± 1.14 before treatment to 0.63 ± 0.98 in the first month, 0.41 ± 1.02 in the third month, and 0.15 ± 0.45 in the sixth month. Only one patient (1.7%) experienced a minor complication; no major complications were recorded in this study. CONCLUSION: CT-guided percutaneous MWA is a minimally invasive and a highly effective and safe approach for the treatment of OO.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesOsteoma, OsteoidTomography, X-Ray ComputedBone NeoplasmsRadiography, InterventionalHumansFemaleMaleRetrospective StudiesAdolescentAdultTreatment OutcomeChildFeasibility StudiesYoung AdultRadiofrequency AblationPain MeasurementSurgery, Computer-AssistedAblation TechniquesMiddle Aged

Stichwörter der Autor:innen

BoneInterventional radiologyMicrowave ablationOsteoid osteomaThermoablation

Autor:innen und Institutionen

  • Department of Radiology, Basaksehir Cam And Sakura City Hospital, Basaksehir 34480, Istanbul, Turkey.
  • Department of Radiology, Basaksehir Cam And Sakura City Hospital, Basaksehir 34480, Istanbul, Turkey. Electronic address: cingozmehmett@hotmail.com.
  • Department of Radiology, Bagcilar Training and Research Hospital, Istanbul, Turkey.

Zitieren

APA

Mutlu, I. N., Cingoz, M., Guzelbey, T., Cingoz, E., & Kilickesmez, O. (2024). Percutaneous CT-Guided Microwave Ablation for the Treatment of Osteoid Osteomas: A Single Center Experience. Academic Radiology. https://doi.org/10.1016/j.acra.2024.02.025

Vancouver

Mutlu IN, Cingoz M, Guzelbey T, Cingoz E, Kilickesmez O. Percutaneous CT-Guided Microwave Ablation for the Treatment of Osteoid Osteomas: A Single Center Experience. Academic Radiology. 2024. doi:10.1016/j.acra.2024.02.025

BibTeX
@article{Mutlu2024,
  author = {Mutlu, Ilhan Nahit and Cingoz, Mehmet and Guzelbey, Tevfik and Cingoz, Eda and Kilickesmez, Ozgur},
  title = {Percutaneous CT-Guided Microwave Ablation for the Treatment of Osteoid Osteomas: A Single Center Experience},
  journal = {Academic Radiology},
  year = {2024},
  doi = {10.1016/j.acra.2024.02.025}
}
Kostenlos starten →