Local reference and achievable dose levels for vascular and enterostomy access procedures in pediatric interventional radiology
Pediatric Radiology · 2023
DOI: 10.1007/s00247-022-05562-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, 2023. Verfasst von Nicholas A Shkumat und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Image-Guided Therapy, Department of Diagnostic Imaging, The Hospital for Sick Children, 555 University Ave., Toronto, ON, M5G 1X8, Canada…. Hauptthemen laut MEDLINE: Enterostomy, Catheterization, Central Venous. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Knowledge of radiation quantities delivered in routine practice is an essential responsibility of a pediatric interventional radiology department. OBJECTIVE: To review radiation indices in frequently performed vascular and enterostomy access procedures at a quaternary pediatric hospital to formulate dosimetric reference levels and achievable levels. MATERIALS AND METHODS: A retrospective review of patient demographics, procedure information and quantitative dose metrics over a 2-year period was performed. Dosimetric details for common procedures (central line insertions, gastrostomy/gastrojejunostomy insertions and maintenance) were evaluated, correlated with demographic data and stratified across five weight groups (0-5 kg, 5-15 kg, 15-30 kg, 30-50 kg, 50-80 kg). Achievable (50th percentile) and reference (75th percentile) levels with confidence intervals were established for each procedure. RESULTS: Within the evaluation period, 3,165 studies satisfied the inclusion criteria. Five were classified as device insertions (peripherally inserted central catheter, n=1,145; port-a-catheter, n=321; central venous line, n=285; gastrostomy-tube [G-tube], n=262, and gastrojejunostomy-tube [GJ-tube], n=66), and two were classified as maintenance procedures (G-tube, n=358, and GJ-tube, n=728, checks, exchanges and reinsertions). Representative reference and achievable levels were calculated for each procedure category and weight group. CONCLUSION: This work highlights the creation of local reference and achievable levels for common pediatric interventional procedures. These data establish a dosimetric reference to understand the quantity of radiation routinely applied, allowing for improved relative radiation risk assessment and enriched communication to interventionalists, health care providers, parents and patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Image-Guided Therapy, Department of Diagnostic Imaging, The Hospital for Sick Children, 555 University Ave., Toronto, ON, M5G 1X8, Canada. nicholas.shkumat@sickkids.ca.
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada. nicholas.shkumat@sickkids.ca.
- Division of Image-Guided Therapy, Department of Diagnostic Imaging, The Hospital for Sick Children, 555 University Ave., Toronto, ON, M5G 1X8, Canada.
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada.
ORCID-Profile: Nicholas A Shkumat
Zitieren
APA
Shkumat, N. A., Chiramel, G. K., Muthusami, P., Parra, D. A., Temple, M. J., & Amaral, J. G. (2023). Local reference and achievable dose levels for vascular and enterostomy access procedures in pediatric interventional radiology. Pediatric Radiology. https://doi.org/10.1007/s00247-022-05562-w
Vancouver
Shkumat NA, Chiramel GK, Muthusami P, Parra DA, Temple MJ, Amaral JG. Local reference and achievable dose levels for vascular and enterostomy access procedures in pediatric interventional radiology. Pediatric Radiology. 2023. doi:10.1007/s00247-022-05562-w
BibTeX
@article{Shkumat2023,
author = {Shkumat, Nicholas A and Chiramel, George K and Muthusami, Prakash and Parra, Dimitri A and Temple, Michael J and Amaral, Joao G},
title = {Local reference and achievable dose levels for vascular and enterostomy access procedures in pediatric interventional radiology},
journal = {Pediatric Radiology},
year = {2023},
doi = {10.1007/s00247-022-05562-w}
}
EUVIMED