A quantitative analysis of the hip shuck test during robotic arm-assisted total hip arthroplasty
HIP International · 2025
DOI: 10.1177/11207000251367640 ↗Kurz gefasst
Fachartikel in der Zeitschrift HIP International, 2025. Verfasst von David Fraser und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Surgery, St Vincent's Private Hospital Northside, Chermside, Queensland, Australia. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Osteoarthritis, Hip, Hip Joint. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Background
The shuck test is a subjective method used intraoperatively to measure soft tissue tension during total hip arthroplasty (THA). This study aimed to introduce and quantify the shuck length vector magnitude in patients undergoing robotic arm-assisted THA, and identify factors affecting its value.
Methods
This prospective cohort study analysed 95 primary THAs performed on 87 patients. Surgical data and intraoperative soft tissue tension measurements were recorded using the Mako robotic arm-assisted system. An exploratory analysis of factors affecting the shuck length vector magnitude was performed.
Results
The mean shuck length vector magnitude was 8.7 mm. Shuck length vector magnitude was significantly higher in males as compared to females ( p = 0.017). A strong inverse correlation was found between increased hip offset and hip length on shuck length vector magnitude ( p < 0.001 and p = 0.004, respectively). Shuck length vector magnitude was not affected by femoral head size ( p = 0.674) and arthritis severity ( p = 0.141).
Conclusions
This study demonstrates that it is possible to quantify soft tissue tension using the shuck test during robotic-assisted THA. Restoring hip offset is crucial for optimising joint stability. Future research should establish a threshold for acceptable shuck length vector magnitude and correlate this with dislocation rates and patient reported outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedic Surgery, St Vincent's Private Hospital Northside, Chermside, Queensland, Australia.
- Orthopaedic Surgery, The Prince Charles Hospital, Metro North Hospital & Health Service, Chermside, Queensland, Australia.
- University of Queensland Centre for Clinical Research, Faculty of Medicine, The University of Queensland, Herston, Queensland, Australia.
- School of Mathematical Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.
- Faculty of Medicine, The University of Queensland, Herston, Queensland, Australia.
ORCID-Profile: Julie F Vermeir, Anthony M Silva
Zitieren
APA
Fraser, D., Vermeir, J. F., O'Connor, P. B., Poli, N., Silva, A. M., & Donnelly, W. J. (2025). A quantitative analysis of the hip shuck test during robotic arm-assisted total hip arthroplasty. HIP International. https://doi.org/10.1177/11207000251367640
Vancouver
Fraser D, Vermeir JF, O'Connor PB, Poli N, Silva AM, Donnelly WJ. A quantitative analysis of the hip shuck test during robotic arm-assisted total hip arthroplasty. HIP International. 2025. doi:10.1177/11207000251367640
BibTeX
@article{Fraser2025,
author = {Fraser, David and Vermeir, Julie F and O'Connor, Patrick B and Poli, Nikola and Silva, Anthony M and Donnelly, William J},
title = {A quantitative analysis of the hip shuck test during robotic arm-assisted total hip arthroplasty},
journal = {HIP International},
year = {2025},
doi = {10.1177/11207000251367640}
}
EUVIMED