EUVIMEDOtkrijte EUVIMED
Randomisierte kontrollierte StudieVergleichsstudieOpen access · CC BY 4.0

Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis

Amanda D Klaassen iD, Justin van Loon iD, Nienke W Willigenburg, Lennard A Koster, Bart L Kaptein, Victor P M van der Hulst, Daniel Haverkamp, Dirk Jan F Moojen, Rudolf W Poolman

HIP International · 2024

DOI: 10.1177/11207000241265653 ↗

At a glance

Randomisierte kontrollierte Studie in HIP International, 2024. Written by Amanda D Klaassen and 8 co-authors. Institution: Department of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands. Major MEDLINE topics: Arthroplasty, Replacement, Hip, Hip Prosthesis, Radiostereometric Analysis, Ceramics. 28 references. The full text is freely available (open access, CC BY 4.0).

SažetakSubjectsBibliografski podaciCiteRelated studies

Abstract (original language)

Introduction

The inelasticity of ceramic bearings might affect primary stability and migration of implants in press-fit total hip arthroplasty (THA). This randomised controlled trial compares migration patterns of the uncemented Delta-TT cup and H-MAX S stem between ceramic and polyethylene liners, up to 5 years follow-up.

Methods

Patients receiving primary press-fit THA were randomly allocated to a ceramic ( n = 28) or polyethylene ( n = 25) liner. Migration was measured using model-based radiostereometric analysis (RSA) at baseline and 1.5, 3, 6, 12, 24 and 60 months postoperatively and compared between groups using mixed models statistical analysis. The focus of this study is on the 2- to 5-year migration of the Delta-TT cup and migration during complete follow-up of the H-MAX S stem up to 5-years.

Results

At 5-year follow-up, mean (95% CI) proximal cup translation was 0.56 (0.37–0.74) mm in ceramic and 0.58 (0.25–0.90) mm in polyethylene ( p = 0.729). The mean change in adduction was 1.05° (0.27–1.82°) in ceramic and 0.78° (−0.16–1.71°) in polyethylene. Mixed modelling showed that all between-group effects were ⩽0.20 mm for translation and ⩽0.22° for rotation at 5 years postoperatively ( p ⩾ 0.23). Mean cup migration between 2 and 5 years was limited (all parameters

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisRadiostereometric AnalysisCeramicsProsthesis DesignProsthesis FailurePolyethyleneHumansMaleFemaleMiddle AgedAgedFollow-Up StudiesTime FactorsAdult

Author keywords

Ceramicmigrationpolyethyleneradiostereometric analysistotal hip arthroplasty

Substances

Polyethylene

Authors and institutions

  • Department of Orthopaedic Surgery, OLVG, Amsterdam, the Netherlands.
  • Department of Orthopaedic Surgery, LUMC, Leiden, the Netherlands.
  • Xpert Clinics Orthopedie Amsterdam, the Netherlands.
  • Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Amsterdam UMC, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands.
  • Department of Radiology, OLVG, Amsterdam, the Netherlands.

ORCID profiles: Amanda D Klaassen, Justin van Loon

Cite

APA

Klaassen, A. D., van Loon, J., Willigenburg, N. W., Koster, L. A., Kaptein, B. L., van der Hulst, V. P. M., Haverkamp, D., Moojen, D. J. F., & Poolman, R. W. (2024). Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis. HIP International. https://doi.org/10.1177/11207000241265653

Vancouver

Klaassen AD, van Loon J, Willigenburg NW, Koster LA, Kaptein BL, van der Hulst VPM, et al. Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis. HIP International. 2024. doi:10.1177/11207000241265653

BibTeX
@article{Klaassen2024,
  author = {Klaassen, Amanda D and van Loon, Justin and Willigenburg, Nienke W and Koster, Lennard A and Kaptein, Bart L and van der Hulst, Victor P M and Haverkamp, Daniel and Moojen, Dirk Jan F and Poolman, Rudolf W},
  title = {Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis},
  journal = {HIP International},
  year = {2024},
  doi = {10.1177/11207000241265653}
}
Start for free →