EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Finite element analysis of femoral component positioning in medial UKA: A focus on varied bone quality

Mengfei Liu, Gang Chen iD, Yupeng He, Haiwen Lu, Yaozong Qin, Chuanlin Mei, Xiaochen Ju

Journal of Orthopaedic Surgery · 2026

DOI: 10.1177/10225536261425782 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, 2026. Verfasst von Mengfei Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, The Second Hospital Affiliated To Henan University of Science and Technology, Luoyang, HA, P.R.China. Hauptthemen laut MEDLINE: Finite Element Analysis, Arthroplasty, Replacement, Knee, Femur, Osteoporosis. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The optimal positioning range for the femoral component in unicompartmental knee arthroplasty (UKA) performed in osteoporotic bone remains undefined. Most existing biomechanical studies have been established using normal bone quality models, whereas limited evidence addresses abnormal bone conditions. Complications involving the operative-side compartment are closely associated with the high revision rates after UKA.

Methods

CT and MRI scans of the right knee of a volunteer without pathological changes were used to construct a three-dimensional finite element model. A normal bone quality UKA model (NB group) was created, and an osteoporotic model (OP group) was generated by reducing the elastic modulus of bone tissue proportionally. Femoral component alignment was set at 0°, as well as 3°, 6°, and 9° of varus and valgus. Stress changes within operative-side structures were quantified and compared between the two models.

Results

(1) In both models, peak stress on the femoral component increased progressively with greater varus alignment, with the OP group consistently demonstrating higher stress values than the NB group. Compared to their respective 0° neutral position, the peak von Mises stress on the femoral component surface increased by 71.8% and 70.8% at 9° of varus in the NB and OP groups, respectively. (2) Peak stresses on the PE insert and on the cortical bone beneath the tibial component increased with both varus and valgus malalignment; the increase was more pronounced under varus. The OP group exhibited higher peak stresses and greater incremental changes than the NB group. Compared to their respective 0° neutral position, the peak von Mises stress on the cortical bone surface beneath the tibial component increased by 50.0% in the NB group and 40.8% in the OP group at 9° varus, and by 14.2% and 27.0%, respectively, at 9° valgus.

Conclusion

Even small coronal-plane deviations (±3°) in femoral component positioning during medial UKA may substantially elevate stresses within the operative-side compartment. Strict control of coronal alignment is essential to avoid varus or valgus and prevent abnormal stress concentrations around the implant. Additionally, the impact of osteoporosis on postoperative biomechanical stability warrants careful consideration to optimize implant design and surgical technique, thereby reducing the risks of aseptic loosening, periprosthetic fracture, and improving long-term outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisArthroplasty, Replacement, KneeFemurOsteoporosisKnee ProsthesisHumansBiomechanical PhenomenaMagnetic Resonance ImagingTomography, X-Ray ComputedImaging, Three-Dimensional

Stichwörter der Autor:innen

femoral component positioningfinite element analysiskneeosteoporosisunicompartmental knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedics, The Second Hospital Affiliated To Henan University of Science and Technology, Luoyang, HA, P.R.China.
  • Department of Joint Surgery, The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, XJ, P.R.China.
  • Department of Knee Surgery, The Third Affiliated Hospital of Foshan University, Foshan, GD, P.R.China.

ORCID-Profile: Gang Chen

Zitieren

APA

Liu, M., Chen, G., He, Y., Lu, H., Qin, Y., Mei, C., & Ju, X. (2026). Finite element analysis of femoral component positioning in medial UKA: A focus on varied bone quality. Journal of Orthopaedic Surgery. https://doi.org/10.1177/10225536261425782

Vancouver

Liu M, Chen G, He Y, Lu H, Qin Y, Mei C, et al. Finite element analysis of femoral component positioning in medial UKA: A focus on varied bone quality. Journal of Orthopaedic Surgery. 2026. doi:10.1177/10225536261425782

BibTeX
@article{Liu2026,
  author = {Liu, Mengfei and Chen, Gang and He, Yupeng and Lu, Haiwen and Qin, Yaozong and Mei, Chuanlin and Ju, Xiaochen},
  title = {Finite element analysis of femoral component positioning in medial UKA: A focus on varied bone quality},
  journal = {Journal of Orthopaedic Surgery},
  year = {2026},
  doi = {10.1177/10225536261425782}
}
Kostenlos starten →