Biomechanical effects of femoral prosthesis misalignment on the structure of the lateral compartment during medial unicompartmental knee arthroplasty in osteoporotic patients
Journal of Orthopaedic Surgery · 2024
DOI: 10.1177/10225536241273924 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, 2024. Verfasst von Mengfei Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, The Second Hospital Affiliated To Henan University of Science and Technology, Luoyang City, P.R.China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Finite Element Analysis, Osteoporosis, Knee Prosthesis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
This study aims to investigate the impact of varying coronal alignments of femoral prostheses on stress and strain distributions within the lateral compartment following unicompartmental knee arthroplasty (UKA) in patients with normal bone density and osteoporosis using finite element analysis. Additionally, it examines the relationship between osteoporosis and the progression of osteoarthritis in the lateral compartment postoperatively.
Methods
UKA models were developed for both normal bone and osteoporotic conditions using a validated finite element model of the knee. Seven alignment conditions for the femoral prosthesis were simulated: 0° (neutral alignment), varus angles of 3°, 6°, and 9°, and valgus angles of 3°, 6°, and 9°, resulting in a total of 14 scenarios. Stress and strain distributions in the meniscus, tibial cartilage, and femoral cartilage of the lateral compartment were evaluated.
Results
The results indicated that stress and strain in the meniscus, tibial cartilage, and femoral cartilage of the lateral compartment increased with greater varus alignment and decreased with greater valgus alignment in both normal and osteoporotic models. At equivalent alignment angles, stress and strain were consistently higher in the osteoporotic model (M2) compared to the normal bone model (M1), although the peak equivalent stress in the tibial cartilage was lower in the M2 model than in the M1 model.
Conclusions
In patients with osteoporosis undergoing fixed-bearing medial UKA, varus malalignment of the femoral prosthesis can lead to increased stress and strain in the lateral compartment’s meniscus, tibial cartilage, and femoral cartilage. These findings suggest that osteoporosis may contribute to abnormal stress and strain distributions in the lateral compartment following UKA, potentially accelerating the progression of osteoarthritis in this region postoperatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, The Second Hospital Affiliated To Henan University of Science and Technology, Luoyang City, P.R.China.
- Department of Joint Surgery, Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, P.R.China.
- The Fifth People's Hospital of Nanhai District, Foshan City, P.R.China.
ORCID-Profile: Xiaochen Ju
Zitieren
APA
Liu, M., Jiang, K., & Ju, X. (2024). Biomechanical effects of femoral prosthesis misalignment on the structure of the lateral compartment during medial unicompartmental knee arthroplasty in osteoporotic patients. Journal of Orthopaedic Surgery. https://doi.org/10.1177/10225536241273924
Vancouver
Liu M, Jiang K, Ju X. Biomechanical effects of femoral prosthesis misalignment on the structure of the lateral compartment during medial unicompartmental knee arthroplasty in osteoporotic patients. Journal of Orthopaedic Surgery. 2024. doi:10.1177/10225536241273924
BibTeX
@article{Liu2024,
author = {Liu, Mengfei and Jiang, Kan and Ju, Xiaochen},
title = {Biomechanical effects of femoral prosthesis misalignment on the structure of the lateral compartment during medial unicompartmental knee arthroplasty in osteoporotic patients},
journal = {Journal of Orthopaedic Surgery},
year = {2024},
doi = {10.1177/10225536241273924}
}
EUVIMED