Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis
PLOS ONE · 2025
DOI: 10.1371/journal.pone.0311210 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2025. Verfasst von Shady A Alshewaier und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia. Hauptthemen laut MEDLINE: Finite Element Analysis, Cartilage, Articular, Arthroplasty, Replacement, Knee, Knee Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deputyship of Research and Innovation, Ministry of Education in Saudi Arabia.
Abstract (Originalsprache)
Knee osteoarthritis (KOA) is a degenerative joint disease predominantly affecting the elderly and is often managed through knee replacement surgeries. West Asians, who frequently engage in activities involving bending and kneeling during their prayers, tend to exhibit distinct bone anatomy compared to the Caucasian population. This research posits that patient-specific, customized knee implants with articular cartilages may lead to reduced post-surgical discomfort and a better implant fit compared to conventional standard implants. This study presents a novel concept and approach for the development of a customized total knee implant with articular cartilages, specifically tailored to simulate loading conditions using finite element analysis (FEA) for the Saudi Arabian population. The research analyses patient-specific customized knee implants with articular cartilages under both pre- and post-implant conditions using a finite element model (FEM). Computed tomography (CT) images of patients were utilized to create a solid model, which was then analysed under various constraints and conditions. The meshing process employed tetrahedral elements, converging with 76,197 nodes and 43,009 elements. The analysis was conducted under different body weights, specifically 75–80 kg and 100–105 kg. Two sets of force and moment were applied: the first with a force of 1000 N and a moment of 1.5 N-m, and the second with a force of 750 N and a moment of 0.8 N-m. The results indicated a 5% reduction in stress with implants designed for a 100 kg body weight, along with a significant reduction in ligament strain when compared to conventional knee joint stresses. This study offers a promising pathway toward reducing post-surgical discomfort. The proposed innovative solution has the potential to revolutionize total knee implant technology, offering enhanced functionality and improved patient outcomes for the Saudi Arabian population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physical Therapy, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia.
- Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia.
- Department of Biotechnology, P.S.R. Engineering College, Sivakasi, India.
- Department of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal, India.
- Machine Design, NMAM Institute of Technology Nitte, Udupi, India.
- Department of Mechanical Engineering, Rajalakshmi Engineering College, Chennai, India.
ORCID-Profile: Mohamed Yacin Sikkandar, S Sabarunisha Begum, Natteri M Sudharsan, Eddie Y K Ng
Förderung
- Deputyship of Research and Innovation, Ministry of Education in Saudi Arabia
Zitieren
APA
Alshewaier, S. A., Sikkandar, M. Y., Almakrami, A. A. A., Begum, S. S., Alassaf, A., AlMohimeed, I., Sundaram, S. M., Poojary, D., Sudharsan, N. M., & Ng, E. Y. K. (2025). Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis. PLOS ONE. https://doi.org/10.1371/journal.pone.0311210
Vancouver
Alshewaier SA, Sikkandar MY, Almakrami AAA, Begum SS, Alassaf A, AlMohimeed I, et al. Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis. PLOS ONE. 2025. doi:10.1371/journal.pone.0311210
BibTeX
@article{Alshewaier2025,
author = {Alshewaier, Shady A and Sikkandar, Mohamed Yacin and Almakrami, Ali Ahmed Ali and Begum, S Sabarunisha and Alassaf, Ahmad and AlMohimeed, Ibrahim and Sundaram, S Meenatchi and Poojary, Dheeraj and Sudharsan, Natteri M and Ng, Eddie Y K},
title = {Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis},
journal = {PLOS ONE},
year = {2025},
doi = {10.1371/journal.pone.0311210}
}
EUVIMED