EUVIMEDEUVIMED entdecken
Vergleichsstudie

Three-dimensional evaluation of lower extremity alignment during gait and standing in healthy elderly individuals: A comparative study using fluoroscopy and 3D to 2D image matching

Tatsuya Soeno, Takashi Sato, Koichi Kobayashi, Ryota Katsumi, Kazutaka Otani, Hiroyuki Kawashima

Bio-Medical Materials and Engineering · 2025

DOI: 10.1177/09592989251315369 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Bio-Medical Materials and Engineering, 2025. Verfasst von Tatsuya Soeno und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science,…. Hauptthemen laut MEDLINE: Gait, Imaging, Three-Dimensional, Lower Extremity, Knee Joint. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The differences in bony alignment of the lower extremities during gait compared to standing remain unclear.

Objective

This study aimed to evaluate three-dimentional (3D) lower extremity alignment in healthy elderly individuals during the stance phase of gait and compare it with static standing alignment.

Methods

Thirty-four knees (9 females, 8 males; mean age 73.2 years) were assessed using single-plane X-ray fluoroscopy and a 3D to two-dimensional (2D) image matching technique. Alignment during stance phase and standing was evaluated in a world coordinate system, using the direction of gravity and frontal X-ray (aligned with the gait direction) as references.

Results

Compared to standing, the femur (3.5°), tibia (3.2°) and tibial joint line relative to the floor (3.3°) exhibited increased lateral inclination during stance phase (p < 0.01). In the transverse plane, the femur showed a significant increase in external rotation during stance phase (5.0°, p < 0.01) compared to standing, with no significant difference in tibial rotation.

Conclusion

Lower extremity alignment significantly differs between static standing and gait, making it challenging to accurately infer the alignment during gait from standing assessments. This approach offers a practical means for assessing functional lower extremity alignment, potentially improving clinical outcomes in realignment surgeries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitImaging, Three-DimensionalLower ExtremityKnee JointStanding PositionHumansFemaleAgedMaleFluoroscopyTibiaAged, 80 and overFemur

Stichwörter der Autor:innen

fluoroscopic imagehealthy individuallower extremity alignmentmid-stance phasetreadmillworld coordinate system

Autor:innen und Institutionen

  • Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan.
  • Department of Orthopedic Surgery, Niigata Medical Center, Niigata, Japan.
  • School of Health Sciences, Faculty of Medicine, Niigata University, Niigata, Japan.
  • Department of Orthopedic Surgery, Nagaoka Red Cross Hospital, Niigata, Japan.

Zitieren

APA

Soeno, T., Sato, T., Kobayashi, K., Katsumi, R., Otani, K., & Kawashima, H. (2025). Three-dimensional evaluation of lower extremity alignment during gait and standing in healthy elderly individuals: A comparative study using fluoroscopy and 3D to 2D image matching. Bio-Medical Materials and Engineering. https://doi.org/10.1177/09592989251315369

Vancouver

Soeno T, Sato T, Kobayashi K, Katsumi R, Otani K, Kawashima H. Three-dimensional evaluation of lower extremity alignment during gait and standing in healthy elderly individuals: A comparative study using fluoroscopy and 3D to 2D image matching. Bio-Medical Materials and Engineering. 2025. doi:10.1177/09592989251315369

BibTeX
@article{Soeno2025,
  author = {Soeno, Tatsuya and Sato, Takashi and Kobayashi, Koichi and Katsumi, Ryota and Otani, Kazutaka and Kawashima, Hiroyuki},
  title = {Three-dimensional evaluation of lower extremity alignment during gait and standing in healthy elderly individuals: A comparative study using fluoroscopy and 3D to 2D image matching},
  journal = {Bio-Medical Materials and Engineering},
  year = {2025},
  doi = {10.1177/09592989251315369}
}
Kostenlos starten →