EUVIMEDEUVIMED entdecken
Vergleichsstudie

3D kinematics of tibiotalar motion in patients with mobile bearing and fixed bearing total ankle arthroplasty: In vivo videofluoroscopic feasibility study

Emily M Abbott, Rohan Bhimani, Rishin J Kadakia, Jason Bariteau, Young-Hui Chang

Gait & Posture · 2024

DOI: 10.1016/j.gaitpost.2024.04.017 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Gait & Posture, 2024. Verfasst von Emily M Abbott und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA; School of Mechanical Engineering, Georgia Institute of Technology, …. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Ankle, Range of Motion, Articular, Feasibility Studies, Ankle Joint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Stryker Corp.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: As total ankle arthroplasty (TAA) is an increasingly common surgical intervention for patients with end-stage ankle arthritis, there is a need to better understand the dynamic performance of prosthetic implants during activities of daily living. Our purpose was to quantify and compare relative tibiotalar motion during gait in persons with a fixed-bearing (FB) and mobile-bearing (MB) total ankle arthroplasty. We hypothesized a FB prosthesis would have lower tibiotalar range of motion (ROM). METHODS: Patients at least 12 months postoperative with either a FB (n=5) or MB (n=3) total ankle arthroplasty were tested. We used high-speed biplanar videoradiography to quantify tibiotalar kinematics during self-selected gait. Angular and linear ROM in three axes were compared between the groups. RESULTS: ROM for dorsiflexion-plantarflexion, internal-external rotation, and inversion-eversion angles in FB subjects averaged 7.47±4.05°, 7.39±3.63°, and 4.51±2.13°, respectively. ROM in MB subjects averaged 6.74±2.04°, 6.28±4.51°, and 5.68±2.81°, respectively. Linear ROM along anteroposterior, mediolateral, and superior-inferior axes in FB subjects averaged 1.47±2.07 mm, 1.13±1.49 mm, and 0.28±0.30 mm, respectively. Linear ROM in MB subjects averaged 0.68±1.44 mm, 0.60±1.41 mm, and 0.20±0.13 mm, respectively. We found no significant difference between the two groups for any of these ROM parameters (p>0.05). CONCLUSION: Total ankle arthroplasty using either FB or MB design appears to confer similar ankle motion during the gait cycle in this biplanar fluoroscopic model. LEVEL OF EVIDENCE: Level IV, case series.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, AnkleRange of Motion, ArticularFeasibility StudiesAnkle JointHumansBiomechanical PhenomenaMaleFemaleMiddle AgedAgedFluoroscopyJoint ProsthesisGaitProsthesis DesignImaging, Three-DimensionalArthritis

Stichwörter der Autor:innen

ArthritisBiomechanicsBiplanar radiographyFixed bearingKinematicsMobile bearingTotal ankle arthroplastyX-ray

Autor:innen und Institutionen

  • School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA; School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
  • Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA. Electronic address: dr.rohanbhimani@gmail.com.
  • Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
  • School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA.

Förderung

  • Stryker Corp

Zitieren

APA

Abbott, E. M., Bhimani, R., Kadakia, R. J., Bariteau, J., & Chang, Y. H. (2024). 3D kinematics of tibiotalar motion in patients with mobile bearing and fixed bearing total ankle arthroplasty: In vivo videofluoroscopic feasibility study. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2024.04.017

Vancouver

Abbott EM, Bhimani R, Kadakia RJ, Bariteau J, Chang YH. 3D kinematics of tibiotalar motion in patients with mobile bearing and fixed bearing total ankle arthroplasty: In vivo videofluoroscopic feasibility study. Gait & Posture. 2024. doi:10.1016/j.gaitpost.2024.04.017

BibTeX
@article{Abbott2024,
  author = {Abbott, Emily M and Bhimani, Rohan and Kadakia, Rishin J and Bariteau, Jason and Chang, Young-Hui},
  title = {3D kinematics of tibiotalar motion in patients with mobile bearing and fixed bearing total ankle arthroplasty: In vivo videofluoroscopic feasibility study},
  journal = {Gait & Posture},
  year = {2024},
  doi = {10.1016/j.gaitpost.2024.04.017}
}
Kostenlos starten →