Comparison of Marker- and Markerless-Derived Lower Body Three-Dimensional Gait Kinematics in Typically Developing Children
Sensors · 2025
DOI: 10.3390/s25144249 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Sensors, 2025. Verfasst von Henrike Greaves und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool L3 3AF, UK. Hauptthemen laut MEDLINE: Gait, Gait Analysis, Lower Extremity. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
Marker-based motion capture is the current gold standard for three-dimensional (3D) gait analysis. This is a highly technical analysis that is time-consuming, and marker application can trigger anxiety in children. One potential solution is to use markerless camera systems instead. The objective of this study was to compare 3D lower limb gait kinematics in children using both marker-based and markerless motion capture methods.
Methods
Ten typically developing children (age 6–13 yrs) completed five barefoot walks at a self-selected speed. A 10-camera marker-based system (Oqus, Qualisys) and a 7-camera markerless system (Miqus, Qualisys) captured synchronised gait data at 85 Hz. Generalised Additive Mixed Models were fitted to the data to identify the random effects of measurement systems, age, and time across the gait cycle. The root-mean-square difference (RMSD) was used to compare the differences between systems.
Results
Significant interactions and differences were observed between the marker-based and markerless systems for most joint angles and planes of motion, particularly with regard to time and age.
Conclusions
Despite differences across all kinematic profiles, the RMSD in this study was comparable to previously published results. Alternative model definitions and kinematic crosstalk in both systems likely explain the differences. Age differences were not consistent across joint levels, suggesting a larger sample size is required to determine how maturation may affect markerless tracking. Further investigation is required to understand the deviations and differences between systems before implementing markerless technology in a clinical setting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool L3 3AF, UK.
- Alder Hey Children's NHS Foundation Trust, Liverpool L12 2AP, UK.
- Research & Innovation Department, Liverpool University Hospitals NHS Foundation Trust, Liverpool L7 8YE, UK.
ORCID-Profile: Henrike Greaves, Antonio Eleuteri, Gabor J Barton, Mark A Robinson, Richard J Foster
Zitieren
APA
Greaves, H., Eleuteri, A., Barton, G. J., Robinson, M. A., Gibbon, K. C., & Foster, R. J. (2025). Comparison of Marker- and Markerless-Derived Lower Body Three-Dimensional Gait Kinematics in Typically Developing Children. Sensors. https://doi.org/10.3390/s25144249
Vancouver
Greaves H, Eleuteri A, Barton GJ, Robinson MA, Gibbon KC, Foster RJ. Comparison of Marker- and Markerless-Derived Lower Body Three-Dimensional Gait Kinematics in Typically Developing Children. Sensors. 2025. doi:10.3390/s25144249
BibTeX
@article{Greaves2025,
author = {Greaves, Henrike and Eleuteri, Antonio and Barton, Gabor J and Robinson, Mark A and Gibbon, Karl C and Foster, Richard J},
title = {Comparison of Marker- and Markerless-Derived Lower Body Three-Dimensional Gait Kinematics in Typically Developing Children},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25144249}
}
EUVIMED