Structural integrity and failure of transfemoral prosthetic socket fabricated using carbon prepreg technique: Influence of fiber orientation and curing conditions
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · 2025
DOI: 10.1177/09544119251372313 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2025. Verfasst von Pimpet Sratong-On und 7 weiteren Autor:innen. Beteiligte Einrichtung: Composite Materials and Lightweight Structures Laboratory, Faculty of Engineering, Thai-Nichi Institute of Technology, Bangkok, 10250 Thailand. Hauptthemen laut MEDLINE: Carbon Fiber, Prosthesis Design, Prosthesis Failure, Femur. Die Arbeit nennt 49 Literaturangaben. Gefördert von: Takahashi Industrial and Economic Research Foundation, Thai-Nichi Institute of Technology.
Abstract (Originalsprache)
This study provides valuable guidance for simplifying fabrication procedures and enhancing the structural integrity and safety of carbon fiber (CF) laminate transfemoral (TF) prosthetic sockets. While the high specific strength of CF laminate sockets offers advantages over conventional plastics, essential production data—their orientation-dependent strength and optimal cure conditions—are lacking, often requiring complex, costly cure cycles. This study investigated (i) the influence of fiber orientation on TF prosthetic CF socket strength via finite element analysis (FEA) during standing, and (ii) optimal single-step Vacuum-Bag-Only (VBO) cure conditions for prepreg in a low-cost conventional oven. Three distinct CF laminates ((45/−45/45/−45), (0/90/0/90), (0/45/−45/90)) were implemented in TF socket finite element (FE) models. Tensile and flexural tests validated FE results and assessed laminate failure modes. Differential Scanning Calorimetry (DSC) investigated cure temperatures, while surface voids were inspected to identify optimal single-step cure conditions. A 1-h isothermal cure at 90°C facilitated resin flow and yielded minimal surface voids. FEA revealed ply orientations insignificantly influenced residual limb pressure. Most plies in the (45/−45/45/−45) CF laminate favorably aligned with oblique deformation for TF socket stabilization during standing. Experimentally, it exhibited the lowest stiffness (10.86 GPa) and strength (161.49 MPa). Nevertheless, its strength is superior to other socket materials and enhances safety through clear pre-fracture signs from ductile failure. Maximum pressure of up to 32.2 kPa at the medial-distal site during standing was insufficient to cause discomfort. These findings provide guidelines for high-quality TF sockets using prepreg by simplifying the fabrication process.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Composite Materials and Lightweight Structures Laboratory, Faculty of Engineering, Thai-Nichi Institute of Technology, Bangkok, 10250 Thailand.
- School of Engineering, Nanyang Polytechnic, 180 Ang Mo Kio Avenue 8 Singapore, 569830 Singapore.
- Sustainable Built Environment Undergraduate Program, Engineering Cluster, Singapore Institute of Technology, 1 Punggol Coast Road Singapore, 828608 Singapore.
- Faculty of Medicine, Sirindhorn School of Prosthetics and Orthotics, Siriraj Hospital, Mahidol University, Bangkok, 10700 Thailand.
ORCID-Profile: Pimpet Sratong-On, Sawanya Suwannawong
Förderung
- Takahashi Industrial and Economic Research Foundation
- Thai-Nichi Institute of Technology
Zitieren
APA
Sratong-On, P., Suwannawong, S., Noothong, W., Pakpia, J., Mun, N. S. W., Aniq Bin Rezaki, M., Kum Lee, C., & Sasaki, K. (2025). Structural integrity and failure of transfemoral prosthetic socket fabricated using carbon prepreg technique: Influence of fiber orientation and curing conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1177/09544119251372313
Vancouver
Sratong-On P, Suwannawong S, Noothong W, Pakpia J, Mun NSW, Aniq Bin Rezaki M, et al. Structural integrity and failure of transfemoral prosthetic socket fabricated using carbon prepreg technique: Influence of fiber orientation and curing conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2025. doi:10.1177/09544119251372313
BibTeX
@article{SratongOn2025,
author = {Sratong-On, Pimpet and Suwannawong, Sawanya and Noothong, Watcharin and Pakpia, Jongsak and Mun, Natasha Shong Wey and Aniq Bin Rezaki, Muhammad and Kum Lee, Chuen and Sasaki, Kazuhiko},
title = {Structural integrity and failure of transfemoral prosthetic socket fabricated using carbon prepreg technique: Influence of fiber orientation and curing conditions},
journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
year = {2025},
doi = {10.1177/09544119251372313}
}
EUVIMED