A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant
Scientific Reports · 2024
DOI: 10.1038/s41598-024-78421-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Reports, 2024. Verfasst von Hans A Gray und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia. Hauptthemen laut MEDLINE: Femur, Femoral Fractures, Finite Element Analysis, Bone-Anchored Prosthesis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Australian Research Council, Blatchford Products Limited, UK.
Abstract (Originalsprache)
Bone-anchored percutaneous implants, commonly referred to as osseointegrated implants, are gaining popularity as an alternative to sockets for attaching a prosthetic limb to an amputated femur. While these implants have several advantages, femoral fractures are relatively common in these patients, occurring in 6.3% of femurs within 4 years. This study aimed to develop a novel method to quantify femoral strength under all possible external loads acting on the distal implant. Finite element analysis was used to explore combinations of forces and moments that, when applied on the bone-anchored implant, were just sufficient to fracture the femur. The 6-dimensional envelope generated in the current study provided a quantitative description of the strength of the femur-implant construct. All the femoral fractures were predicted in the trochanteric region, corresponding to where most in vivo fractures have been reported. The 6-dimensional envelopes developed in the current study may be useful in the design of fail-safe devices that could reduce femoral fractures in patients with bone-anchored percutaneous femoral implants. The framework presented may also be used for determining patient suitability for bone-anchored percutaneous implants, and for evaluating the functional performance of implant designs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia.
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia. pvlee@unimelb.edu.au.
ORCID-Profile: Hans A Gray, Ryan Tiew, Dale L Robinson, David Ackland, Peter V S Lee
Förderung
- Australian Research Council
- Blatchford Products Limited, UK
Zitieren
APA
Gray, H. A., Tiew, R., Robinson, D. L., Ackland, D., & Lee, P. V. S. (2024). A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant. Scientific Reports. https://doi.org/10.1038/s41598-024-78421-3
Vancouver
Gray HA, Tiew R, Robinson DL, Ackland D, Lee PVS. A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant. Scientific Reports. 2024. doi:10.1038/s41598-024-78421-3
BibTeX
@article{Gray2024,
author = {Gray, Hans A and Tiew, Ryan and Robinson, Dale L and Ackland, David and Lee, Peter V S},
title = {A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant},
journal = {Scientific Reports},
year = {2024},
doi = {10.1038/s41598-024-78421-3}
}
EUVIMED