Numerical investigation of the effect of weir installation angle on the air-separation performance of a self-priming pump
Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering · 28.07.2026
DOI: 10.1177/09544089261471962 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, online erschienen am 28.07.2026. Verfasst von Minki Kim und 3 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Hanil Ilseok Foundation, National Research Foundation of Korea.
Abstract (Originalsprache)
A self-priming centrifugal pump is designed to automatically evacuate air from the suction line and establish a stable liquid flow without external priming. During the start-up phase, the pump handles a gas–liquid mixture that often leads to suction failure; thus, the separation tank must effectively decouple the air from the recirculating water. While the air–water separation weir is a critical component for this process, its geometric optimization has lacked comprehensive numerical quantification. This study investigates the impact of the weir installation angle (0°, 9°, and 18°) on air removal efficiency using two complementary numerical approaches: an unsteady two-dimensional volume of fluid model is used to qualitatively examine the transient air–water interface during the initial priming stage, while a three-dimensional dispersed phase model is used as the quantitative basis for assessing micro-bubble removal performance. The two-dimensional volume of fluid results indicate that a 9° angle promotes rapid initial air exhaust by aligning the internal flow. However, at 18°, excessive turbulence induces air phase fragmentation, causing undesired recirculation that slightly reduces the initial exhaust efficiency. Conversely, the dispersed phase analysis shows that separation efficiency ( η sep ) peaks at 96% for the 18° case, compared to approximately 70% for the 0° and 9° cases. This indicates that, among the three tested configurations, the 9° case is more favorable for initial evacuation, whereas the steeper 18° case is more favorable for guiding fine micro-bubbles toward separation zones during steady operation. These results show that the preferable weir-angle configuration depends on the prioritized performance metric within the tested design space—the initial priming speed versus the long-term micro-bubble removal. The combined interpretation of qualitative volume of fluid interface observations and quantitative dispersed phase particle-tracking metrics provides a physically consistent framework for evaluating self-priming behavior.
Förderung
- Hanil Ilseok Foundation
- National Research Foundation of Korea
Zitieren
APA
Kim, M., Kim, M., Hahn, B., & Kim, J. (2026). Numerical investigation of the effect of weir installation angle on the air-separation performance of a self-priming pump. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. https://doi.org/10.1177/09544089261471962
Vancouver
Kim M, Kim M, Hahn B, Kim J. Numerical investigation of the effect of weir installation angle on the air-separation performance of a self-priming pump. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. 2026. doi:10.1177/09544089261471962
BibTeX
@article{Kim2026,
author = {Kim, Minki and Kim, Minho and Hahn, Bongsu and Kim, Jaekwang},
title = {Numerical investigation of the effect of weir installation angle on the air-separation performance of a self-priming pump},
journal = {Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering},
year = {2026},
doi = {10.1177/09544089261471962}
}
EUVIMED