Comparative evaluation of translucency changes in pre-shaded and externally stained CAD-CAM ceramics after thermocycling aging
Technology and Health Care · 07.11.2026
DOI: 10.1177/09287329261505074 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology and Health Care, online erschienen am 07.11.2026. Verfasst von Satheesh B Haralur und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Deanship of Research and Graduate Studies at King Khalid University.
Abstract (Originalsprache)
Background
Matching translucency, in addition to shade, ensures that restorations blend harmoniously with natural teeth by replicating depth, vitality, masking capability, and enduring esthetic longevity.
Objective
This in vitro study investigated the influence of thermocycling aging on the translucency parameter (TP) of pre-shaded and externally stained CAD-CAM all-ceramic materials.
Methods
Square-shaped ceramic discs (11 × 11 × 1.5 mm; n = 20 per group) were fabricated from lithium disilicate (LDS-CAD), zirconia-reinforced lithium silicate (ZLS-CAD), and high-translucency monolithic zirconia (MZ-HT). Ten specimens from each group were further processed with the corresponding external stains (IPS e.max CAD Crystall, Celtra universal stains, or Ceramill liquid). Baseline TP values were determined spectrophotometrically from the color difference between white and black backgrounds. Specimens were then subjected to 10,000 thermocycles between 5 °C and 55 °C, after which TP values were remeasured. Data were analyzed using three-way mixed ANOVA and Tukey's HSD test (p < 0.05).
Results
At baseline, pre-shaded MZ-HT exhibited the highest TP values (20.51 ± 2.17), followed by pre-shaded ZLS-CAD (16.92 ± 0.83) and LDS-CAD (15.07 ± 1.29). External staining led to a marginal reduction in TP across all groups. Three-way mixed ANOVA revealed significant effects of material and coloration technique on TP values. A significant Material × Aging interaction indicated that the effect of thermocycling differed among ceramic materials, with zirconia showing the greatest change following aging.
Conclusion
Translucency was significantly influenced by ceramic material and coloration technique. The effect of thermocycling aging on TP was material-dependent, with high-translucency zirconia showing the greatest change.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia.
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia.
ORCID-Profile: Satheesh B Haralur
Förderung
- Deanship of Research and Graduate Studies at King Khalid University
Zitieren
APA
Haralur, S. B., Alqahtani, S. M., Alawwadh, S. M., Alosman, S. S. M., Alqarni, M. A., & Alqahtani, S. M. (2026). Comparative evaluation of translucency changes in pre-shaded and externally stained CAD-CAM ceramics after thermocycling aging. Technology and Health Care. https://doi.org/10.1177/09287329261505074
Vancouver
Haralur SB, Alqahtani SM, Alawwadh SM, Alosman SSM, Alqarni MA, Alqahtani SM. Comparative evaluation of translucency changes in pre-shaded and externally stained CAD-CAM ceramics after thermocycling aging. Technology and Health Care. 2026. doi:10.1177/09287329261505074