EUVIMEDEUVIMED entdecken
Crossref

Design, construction and application of a grating-based X-ray phase contrast imaging system under laboratory conditions

Xiaojia Wei, Haowei Wang, Hongyu Zhao, Pengfei Tang, Yanhui Chen, Ang Li, Jianfei Zhang

Journal of X-Ray Science and Technology · 04.11.2026

DOI: 10.1177/08953996261451154 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 04.11.2026. Verfasst von Xiaojia Wei und 6 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National key research and development program of China, Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

X-ray phase-contrast imaging enables nondestructive visualization of internal structures in weakly absorbing samples, attracting increasing interest for laboratory-based applications. However, translating this technology from synchrotron facilities to laboratory settings requires rigorous parameter optimization to overcome limited source brilliance. In this work, a practical grating-based X-ray phase-contrast imaging system was systematically designed and constructed within a standard laboratory CT chamber. Key parameters, including the grating duty cycle, phase-shift conditions, and geometric constraints, were theoretically optimized to balance fringe visibility and photon flux. The required gratings were fabricated in-house using an optimized lithography and electroplating process. Experimental results using a two-step phase-shifting method demonstrated high-quality imaging capabilities across diverse applications. Specifically, tests on cotton swabs, oxidized 904L stainless steel, and fish bones highlighted the system's versatility in biomedical research and industrial failure analysis. Quantitative analysis revealed that the system significantly enhances feature detectability, achieving a Contrast-to-Noise Ratio (CNR) of 8.5 for biological microstructures—an approximately 7-fold improvement over conventional absorption imaging (CNR 1.2). This work provides a reproducible framework and validated parameter set for implementing high-sensitivity phase-contrast imaging under accessible laboratory conditions.

Förderung

  • National key research and development program of China
  • Natural Science Foundation of China

Zitieren

APA

Wei, X., Wang, H., Zhao, H., Tang, P., Chen, Y., Li, A., & Zhang, J. (2026). Design, construction and application of a grating-based X-ray phase contrast imaging system under laboratory conditions. Journal of X-Ray Science and Technology. https://doi.org/10.1177/08953996261451154

Vancouver

Wei X, Wang H, Zhao H, Tang P, Chen Y, Li A, et al. Design, construction and application of a grating-based X-ray phase contrast imaging system under laboratory conditions. Journal of X-Ray Science and Technology. 2026. doi:10.1177/08953996261451154

BibTeX
@article{Wei2026,
  author = {Wei, Xiaojia and Wang, Haowei and Zhao, Hongyu and Tang, Pengfei and Chen, Yanhui and Li, Ang and Zhang, Jianfei},
  title = {Design, construction and application of a grating-based X-ray phase contrast imaging system under laboratory conditions},
  journal = {Journal of X-Ray Science and Technology},
  year = {2026},
  doi = {10.1177/08953996261451154}
}
Kostenlos starten →