EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multidirectional x-ray phase-contrast imaging with 1D modulators

Luca Brombal, Cristian David Tibambre Heredia, Ashkan Ajeer, Andrew L. Coathup, Paola Perion, Marco Endrizzi

Applied Physics Letters · 09.11.2026 · 129 (19)

DOI: 10.1063/5.0354473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 09.11.2026. Verfasst von Luca Brombal und 5 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero dell'Università e della Ricerca, EPSRC.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Beam-tracking (BT) is an x-ray phase-contrast imaging technique that requires a single absorption mask, making it simpler to implement than approaches relying on two or more masks or gratings, such as edge-illumination or grating interferometry. Conventional 1D-BT, based on linear masks splitting the beam into individual beamlets, is sensitive to refraction and dark-field signals only along the direction transverse to the beamlets, while multidirectional sensitivity requires 2D masks. However, 2D masks suffer from reduced photon transmission and a quadratic increase in the number of stepping positions needed for full sample illumination, resulting in longer acquisition times. Here, we present multi1D-BT, an acquisition scheme that achieves multidirectional sensitivity in the transmission and differential phase (refraction) channels using a 1D mask, by combining two consecutive acquisitions rotated 90° with respect to each other. The method is validated on a polymethyl methacrylate test phantom and an ex vivo insect specimen, comparing multi1D-BT against 2D-BT acquisitions obtained with 2D structured modulators with (nearly) matching periods and apertures. In our experiments, multi1D-BT achieved a three times faster acquisition with similar or better image quality compared to conventional 2D-BT: the signal-to-noise ratio in the refraction signal was 35%–70% higher, and up to two times higher when compared at matched exposure time, while the contrast-to-noise ratio in the transmission signal was more than doubled. These findings indicate that multi1D-BT can provide fast, multidirectional differential phase and transmission imaging using simpler and more widely available 1D modulators, at the cost of requiring image registration between the two orthogonal acquisitions.

Förderung

  • Ministero dell'Università e della Ricerca
  • EPSRC

Zitieren

APA

Brombal, L., Heredia, C. D. T., Ajeer, A., Coathup, A. L., Perion, P., & Endrizzi, M. (2026). Multidirectional x-ray phase-contrast imaging with 1D modulators. Applied Physics Letters, 129(19). https://doi.org/10.1063/5.0354473

Vancouver

Brombal L, Heredia CDT, Ajeer A, Coathup AL, Perion P, Endrizzi M. Multidirectional x-ray phase-contrast imaging with 1D modulators. Applied Physics Letters. 2026;129(19). doi:10.1063/5.0354473

BibTeX
@article{Brombal2026,
  author = {Brombal, Luca and Heredia, Cristian David Tibambre and Ajeer, Ashkan and Coathup, Andrew L. and Perion, Paola and Endrizzi, Marco},
  title = {Multidirectional x-ray phase-contrast imaging with 1D modulators},
  journal = {Applied Physics Letters},
  year = {2026},
  volume = {129},
  number = {19},
  doi = {10.1063/5.0354473}
}
Kostenlos starten →