EUVIMEDEUVIMED entdecken
Crossref

Improved L1/L2 minimization algorithm for segmental limited-angle CT reconstruction

Changcheng Gong, Hongxia Wang, Jie Chen

Journal of X-Ray Science and Technology · 2026-05 · 34 (3) · 314-327

DOI: 10.1177/08953996261439063 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 09.04.2026. Verfasst von Changcheng Gong und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, China. Hauptthemen laut MEDLINE: Algorithms, Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit nennt 41 Literaturangaben. Gefördert von: General Project of Chongqing Natural Science Foundation, Youth Project of Science and Technology Research Program of Chongqing Education Commission of China, Scientific Research Foundation of Chongqing Technology and Business University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Computed tomography (CT) technology is widely used in medical imaging, industrial non-destructive testing, and archaeological exploration. However, its application is often limited by issues such as high radiation doses or long scanning time. This paper utilizes the segmental limited-angle (SLA) sampling strategy to address these issues. However, SLA projections inherit limited-angle sampling properties, and shading artifacts still exist in the reconstructed images. To address this issue, we introduce the L1/L2 ratio of image gradients as a regularization term into SLA CT to construct a reconstruction model. The L1/L2 ratio is scale-invariant and can better approximate the L0 norm, shows great potential for improving image quality. To solve this model, we propose an improved L1/L2 minimization algorithm. First linearize the data fidelity term, and then use the Fast Fourier Transform (FFT) to accelerate the computation process. Finally, we employ the alternating direction method to obtain the reconstructed image. Numerical simulations and real CT data experiments demonstrate that the L1/L2 method outperforms other competing methods, and it can effectively preserve image structures and some details.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsTomography, X-Ray ComputedImage Processing, Computer-AssistedPhantoms, ImagingComputer SimulationHumansFourier Analysis

Stichwörter der Autor:innen

L1/L2 minimizationcomputed tomographyimage reconstructionsegmental limited-angle

Autor:innen und Institutionen

  • School of Mathematics and Statistics, Chongqing Technology and Business University, Chongqing, China.
  • Chongqing Key Laboratory of Statistical Intelligent Computing and Monitoring, Chongqing Technology and Business University, Chongqing, China.

Förderung

  • General Project of Chongqing Natural Science Foundation
  • Youth Project of Science and Technology Research Program of Chongqing Education Commission of China
  • Scientific Research Foundation of Chongqing Technology and Business University
  • Graduate Research and Innovation Foundation of Chongqing

Zitieren

APA

Gong, C., Wang, H., & Chen, J. (2026). Improved L1/L2 minimization algorithm for segmental limited-angle CT reconstruction. Journal of X-Ray Science and Technology, 34(3), 314-327. https://doi.org/10.1177/08953996261439063

Vancouver

Gong C, Wang H, Chen J. Improved L1/L2 minimization algorithm for segmental limited-angle CT reconstruction. Journal of X-Ray Science and Technology. 2026;34(3):314-327. doi:10.1177/08953996261439063

BibTeX
@article{Gong2026,
  author = {Gong, Changcheng and Wang, Hongxia and Chen, Jie},
  title = {Improved L1/L2 minimization algorithm for segmental limited-angle CT reconstruction},
  journal = {Journal of X-Ray Science and Technology},
  year = {2026},
  volume = {34},
  number = {3},
  pages = {314--327},
  doi = {10.1177/08953996261439063}
}
Kostenlos starten →