EUVIMEDEUVIMED entdecken
Crossref

Quad-Net: Quad-Domain Network for CT Metal Artifact Reduction

Zilong Li, Qi Gao, Yaping Wu, Chuang Niu, Junping Zhang, Meiyun Wang, Ge Wang, Hongming Shan

IEEE Transactions on Medical Imaging · 2024

DOI: 10.1109/tmi.2024.3351722 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024. Verfasst von Zilong Li und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Artifacts, Tomography, X-Ray Computed, Metals. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Sailing Program, Joint Fund of Henan Province Science and Technology Research and Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metal implants and other high-density objects in patients introduce severe streaking artifacts in CT images, compromising image quality and diagnostic performance. Although various methods were developed for CT metal artifact reduction over the past decades, including the latest dual-domain deep networks, remaining metal artifacts are still clinically challenging in many cases. Here we extend the state-of-the-art dual-domain deep network approach into a quad-domain counterpart so that all the features in the sinogram, image, and their corresponding Fourier domains are synergized to eliminate metal artifacts optimally without compromising structural subtleties. Our proposed quad-domain network for MAR, referred to as Quad-Net, takes little additional computational cost since the Fourier transform is highly efficient, and works across the four receptive fields to learn both global and local features as well as their relations. Specifically, we first design a Sinogram-Fourier Restoration Network (SFR-Net) in the sinogram domain and its Fourier space to faithfully inpaint metal-corrupted traces. Then, we couple SFR-Net with an Image-Fourier Refinement Network (IFR-Net) which takes both an image and its Fourier spectrum to improve a CT image reconstructed from the SFR-Net output using cross-domain contextual information. Quad-Net is trained on clinical datasets to minimize a composite loss function. Quad-Net does not require precise metal masks, which is of great importance in clinical practice. Our experimental results demonstrate the superiority of Quad-Net over the state-of-the-art MAR methods quantitatively, visually, and statistically. The Quad-Net code is publicly available at https://github.com/longzilicart/Quad-Net.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsTomography, X-Ray ComputedMetalsHumansFourier AnalysisAlgorithmsDeep LearningProstheses and ImplantsImage Processing, Computer-AssistedPhantoms, Imaging

Substanzen

Metals

Förderung

  • National Natural Science Foundation of China
  • Shanghai Sailing Program
  • Joint Fund of Henan Province Science and Technology Research and Development Program
  • Shanghai Municipal Science and Technology Major Project
  • ZJLaboratory

Zitieren

APA

Li, Z., Gao, Q., Wu, Y., Niu, C., Zhang, J., Wang, M., Wang, G., & Shan, H. (2024). Quad-Net: Quad-Domain Network for CT Metal Artifact Reduction. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2024.3351722

Vancouver

Li Z, Gao Q, Wu Y, Niu C, Zhang J, Wang M, et al. Quad-Net: Quad-Domain Network for CT Metal Artifact Reduction. IEEE Transactions on Medical Imaging. 2024. doi:10.1109/tmi.2024.3351722

BibTeX
@article{Li2024,
  author = {Li, Zilong and Gao, Qi and Wu, Yaping and Niu, Chuang and Zhang, Junping and Wang, Meiyun and Wang, Ge and Shan, Hongming},
  title = {Quad-Net: Quad-Domain Network for CT Metal Artifact Reduction},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2024},
  doi = {10.1109/tmi.2024.3351722}
}
Kostenlos starten →