A new era of high-resolution CT diagnostics of the lung: improved image quality, detailed morphology, and reduced radiation dose with high-resolution photon-counting CT of the lungs compared to high-resolution energy-integrated CT
Acta Radiologica · 2024
DOI: 10.1177/02841851241269918 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Radiologica, 2024. Verfasst von Marie-Louise Aurumskjöld und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage, Lung. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
High-resolution computed tomography (HRCT) is dependent on detailed morphology in diagnostic assessment of interstitial lung diseases. Photon-counting CT (PCCT) enables improved resolution while reducing radiation.
Purpose
To compare if the image quality, detailed morphology, and radiation dose in HRCT of the lung improves with PCCT compared to energy-integrated CT (EICT). Material and Methods HRCT with PCCT in patients with body mass index (BMI) from normal to obese, previously examined with different EICT were included. They were evaluated in a five-step scale for image quality according to Quality Criteria for CT (Diagnostic Requirement of the ImPACT group-European standardization). In addition, ground-glass opacities, bronchiectasis, emphysema, nodules, and subpleural detailed morphology (≤1 cm from the pleural border) were evaluated by three independent thoracic and/or pediatric radiologists. Visual grading characteristics (VGC) were used for comparison of image quality and detailed morphology and Fleiss kappa for intra-observer variability. Dose-length product (DLP) and CT dose index-volume (CTDI vol ) were collected to calculate effective radiation dose.
Results
HRCT with PCCT in 52 women and 48 men (mean age=67.2 ± 13.6 years; age range=27–87 years; BMI=26.9 kg/m 2 ; range=18.6–45 kg/m 2 ) previously examined with EICT (mean age=65.3 ± 13.6 years; age range=27–85 years; BMI=27 kg/m 2 ; range=18.9–45 kg/m 2 ) were included. There were significant differences in image quality for all entities in favor of PCCT. The radiation dose was reduced with PCCT by 47% in all, particularly pronounced in obese with 48.5%.
Conclusion
Image quality, detailed morphology, and radiation dose, particularly in obese patients, were significantly improved in HRCT with PCCT compared to conventional EICT. The new technique enables visualization of subpleural structures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden.
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden.
- Department of Clinical Sciences, Lund University, Lund, Sweden.
ORCID-Profile: Marie-Louise Aurumskjöld, Gracijela Bozovic
Zitieren
APA
Aurumskjöld, M. L., Sjunnesson, L., Pistea, A., Ásbjörnsson, G., Wellman, F., & Bozovic, G. (2024). A new era of high-resolution CT diagnostics of the lung: improved image quality, detailed morphology, and reduced radiation dose with high-resolution photon-counting CT of the lungs compared to high-resolution energy-integrated CT. Acta Radiologica. https://doi.org/10.1177/02841851241269918
Vancouver
Aurumskjöld ML, Sjunnesson L, Pistea A, Ásbjörnsson G, Wellman F, Bozovic G. A new era of high-resolution CT diagnostics of the lung: improved image quality, detailed morphology, and reduced radiation dose with high-resolution photon-counting CT of the lungs compared to high-resolution energy-integrated CT. Acta Radiologica. 2024. doi:10.1177/02841851241269918
BibTeX
@article{Aurumskjld2024,
author = {Aurumskjöld, Marie-Louise and Sjunnesson, Lotta and Pistea, Adrian and Ásbjörnsson, Gylfi and Wellman, Fredrik and Bozovic, Gracijela},
title = {A new era of high-resolution CT diagnostics of the lung: improved image quality, detailed morphology, and reduced radiation dose with high-resolution photon-counting CT of the lungs compared to high-resolution energy-integrated CT},
journal = {Acta Radiologica},
year = {2024},
doi = {10.1177/02841851241269918}
}