Automatic hepatic steatosis quantification using low-dose CT with deep learning-based noise reduction and CT fat fraction analysis software
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag054 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Sung Joon Youn und 4 weiteren Autor:innen. Beteiligte Einrichtung: Seoul National University College of Medicine, Seoul 03080, Korea. Hauptthemen laut MEDLINE: Fatty Liver, Tomography, X-Ray Computed, Deep Learning, Radiation Dosage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: SNUH, ClariPi., Ltd..
Abstract (Originalsprache)
Objectives
To evaluate the accuracy of CT-derived fat fraction (CDFF) software for quantifying hepatic steatosis at various radiation doses, using MRI-derived proton density fat fraction (MRI-PDFF) as the reference standard, and examines the impact of deep learning (DL)-based noise reduction on CDFF accuracy in low-dose CT (LDCT) scans.
Methods
We conducted a retrospective analysis of 125 living liver donor candidates who underwent non-contrast CT and MRI between July 2016 and December 2017. CDFF was measured on full-dose and simulated LDCT scans at 50%, 25%, and 10% radiation doses. DL-based denoising reconstruction (DLDR) was applied to LDCT scans for CDFF recalculation. The accuracy of CDFF was compared with MRI-PDFF using Pearson correlation coefficients and receiver operating characteristic (ROC) curve analysis, focusing on the effects of radiation dose and DLDR.
Results
Of the 125 participants (mean age 38 ± 10 years; 77 males), 29 (23%) had hepatic steatosis (MRI-PDFF ≥5%). Full-dose CDFF showed moderate correlation with MRI-PDFF (r = 0.728; P < .001). Correlation decreased with lower doses (r = 0.684-0.725) but improved with DLDR (r = 0.725-0.736). ROC AUC for diagnosing hepatic steatosis was 0.82 for full-dose CDFF, with similar performance across other doses except 10%.
Conclusions
CDFF accuracy declines at lower radiation doses, but DLDR enhances accuracy, improving alignment with MRI-PDFF, especially at reduced doses. Advances in knowledge DLDR significantly enhances the accuracy of CDFF accuracy at lower radiation doses, enabling high diagnostic performance for hepatic steatosis while potentially reducing patient radiation exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Seoul National University College of Medicine, Seoul 03080, Korea.
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul 03080, Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Korea.
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Korea.
- ClariPi Research, ClariPi, Seoul 03088, Korea.
ORCID-Profile: Sung Joon Youn, Sun Kyung Jeon, Jeong Hee Yoon, Chulkyun Ahn, Jeong Min Lee
Förderung
- SNUH
- ClariPi., Ltd.
Zitieren
APA
Youn, S. J., Jeon, S. K., Yoon, J. H., Ahn, C., & Lee, J. M. (2026). Automatic hepatic steatosis quantification using low-dose CT with deep learning-based noise reduction and CT fat fraction analysis software. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag054
Vancouver
Youn SJ, Jeon SK, Yoon JH, Ahn C, Lee JM. Automatic hepatic steatosis quantification using low-dose CT with deep learning-based noise reduction and CT fat fraction analysis software. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag054
BibTeX
@article{Youn2026,
author = {Youn, Sung Joon and Jeon, Sun Kyung and Yoon, Jeong Hee and Ahn, Chulkyun and Lee, Jeong Min},
title = {Automatic hepatic steatosis quantification using low-dose CT with deep learning-based noise reduction and CT fat fraction analysis software},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag054}
}