EUVIMEDEUVIMED entdecken
Crossref

Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks

Mohammad Rawashdeh, Abdel-Baset Bani Yaseen, Mark McEntee, Andrew England, Praveen Kumar, Charbel Saade

Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2024

DOI: 10.3233/xst-230276 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2024. Verfasst von Mohammad Rawashdeh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health Sciences, Gulf Medical University, Ajman, UAE. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage, Spine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS: Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol) and DLP values. RESULTS: Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients’ mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS: This research demonstrates a wide range of variability in CTDI (vol) and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedRadiation DosageSpineHumansJordanMaleFemaleAdultMiddle AgedAgedBenchmarkingDiagnostic Reference LevelsAdolescentYoung AdultChildAged, 80 and over

Stichwörter der Autor:innen

DRLDiagnostic reference levelcomputed tomographydose optimizationradiation dose

Autor:innen und Institutionen

  • Faculty of Health Sciences, Gulf Medical University, Ajman, UAE.
  • Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan.
  • Faculty of Health, School of Clinical Science, Queensland University of Technology, Queensland, Australia.
  • Discipline of Medical Imaging and Radiation Therapy, Brookfield Health Sciences, University College Cork, Cork, Ireland.

Zitieren

APA

Rawashdeh, M., Bani Yaseen, A. B., McEntee, M., England, A., Kumar, P., & Saade, C. (2024). Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-230276

Vancouver

Rawashdeh M, Bani Yaseen AB, McEntee M, England A, Kumar P, Saade C. Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2024. doi:10.3233/xst-230276

BibTeX
@article{Rawashdeh2024,
  author = {Rawashdeh, Mohammad and Bani Yaseen, Abdel-Baset and McEntee, Mark and England, Andrew and Kumar, Praveen and Saade, Charbel},
  title = {Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2024},
  doi = {10.3233/xst-230276}
}
Kostenlos starten →