Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks
Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2024
DOI: 10.3233/xst-230276 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2024. Verfasst von Mohammad Rawashdeh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health Sciences, Gulf Medical University, Ajman, UAE. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage, Spine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS: Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol) and DLP values. RESULTS: Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients’ mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS: This research demonstrates a wide range of variability in CTDI (vol) and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Health Sciences, Gulf Medical University, Ajman, UAE.
- Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan.
- Faculty of Health, School of Clinical Science, Queensland University of Technology, Queensland, Australia.
- Discipline of Medical Imaging and Radiation Therapy, Brookfield Health Sciences, University College Cork, Cork, Ireland.
Zitieren
APA
Rawashdeh, M., Bani Yaseen, A. B., McEntee, M., England, A., Kumar, P., & Saade, C. (2024). Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-230276
Vancouver
Rawashdeh M, Bani Yaseen AB, McEntee M, England A, Kumar P, Saade C. Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2024. doi:10.3233/xst-230276
BibTeX
@article{Rawashdeh2024,
author = {Rawashdeh, Mohammad and Bani Yaseen, Abdel-Baset and McEntee, Mark and England, Andrew and Kumar, Praveen and Saade, Charbel},
title = {Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks},
journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
year = {2024},
doi = {10.3233/xst-230276}
}
EUVIMED