The usefulness of contrast-enhanced subtraction magnetic resonance imaging for detecting endoleaks after endovascular aortic repair with prophylactic intraoperative sac embolization
Acta Radiologica · 2024
DOI: 10.1177/02841851241263987 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Radiologica, 2024. Verfasst von Atsufumi Kamisako und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Wakayama Medical University, Wakayamashi, Wakayama, Japan. Hauptthemen laut MEDLINE: Endoleak, Contrast Media, Aortic Aneurysm, Abdominal, Endovascular Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Background
Metallic and hyperdense artifacts and T1-shortening substances in the abdominal aortic aneurysm (AAA) sac generated by embolic materials and lipiodol pose challenges in the identification of endoleaks on follow-up computed tomography (CT) or magnetic resonance imaging (MRI).
Purpose
To evaluate the usefulness of contrast-enhanced subtraction MRI (CES-MRI) for detecting endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) with intraoperative AAA sac embolization compared with CE-CT, this study was conducted. Material and Methods In this study, 28 consecutive patients who underwent EVAR with prophylactic AAA sac embolization were included. All patients underwent CES-MRI and CE-CT to detect endoleaks. The definitive diagnosis of endoleaks was a consensus reading of CE-CT and CES-MRI by two certified radiologists, in addition to angiography or reproducible radiological findings in the observational examination. Analysis was performed to evaluate which examination was better for detecting endoleaks.
Results
The sensitivity, specificity, and area under the curve of CE-CT and CES-MRI according to observer 1 were 50%, 100%, and 0.813 (95% confidence interval [CI] = 0.625–1.00) and 100%, 95%, and 0.997 (95% CI = 0.984–1.00), respectively, and those according to observer 2 were 50%, 100%, and 0.750 (95% CI = 0.514–0.986) and 100%, 95%, and 0.969 (95% CI = 0.903–1.00), respectively. Intolerable artifacts were significantly observed on CE-CT. The severity of the artifacts did not depend on the stent graft on CT and MRI.
Conclusion
Although no significant difference was observed, CES-MRI tended to have better accuracy for endoleak detection in EVAR with intraoperative AAA sac embolization than CE-CT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Wakayama Medical University, Wakayamashi, Wakayama, Japan.
- Department of Radiology, Tokyo Medical University, Shinjyukuku, Tokyo, Japan.
ORCID-Profile: Motoki Nakai, Taro Tanaka, Yukinori Okada, Kazuhiro Saito
Zitieren
APA
Kamisako, A., Nakai, M., Saguchi, T., Tanaka, T., Okada, Y., Ishida, M., & Saito, K. (2024). The usefulness of contrast-enhanced subtraction magnetic resonance imaging for detecting endoleaks after endovascular aortic repair with prophylactic intraoperative sac embolization. Acta Radiologica. https://doi.org/10.1177/02841851241263987
Vancouver
Kamisako A, Nakai M, Saguchi T, Tanaka T, Okada Y, Ishida M, et al. The usefulness of contrast-enhanced subtraction magnetic resonance imaging for detecting endoleaks after endovascular aortic repair with prophylactic intraoperative sac embolization. Acta Radiologica. 2024. doi:10.1177/02841851241263987
BibTeX
@article{Kamisako2024,
author = {Kamisako, Atsufumi and Nakai, Motoki and Saguchi, Toru and Tanaka, Taro and Okada, Yukinori and Ishida, Masanori and Saito, Kazuhiro},
title = {The usefulness of contrast-enhanced subtraction magnetic resonance imaging for detecting endoleaks after endovascular aortic repair with prophylactic intraoperative sac embolization},
journal = {Acta Radiologica},
year = {2024},
doi = {10.1177/02841851241263987}
}