Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2024. Verfasst von Dagmar Morell-Hofert und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Medical University Innsbruck, Innsbruck, Austria. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Blood Vessel Prosthesis Implantation, Endovascular Procedures. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 45 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Endoleaks are the most common complication after endovascular aneurysm repair (EVAR). Computed tomography angiography (CTA) is presently the golden standard for lifelong surveillance after EVAR. Several studies and meta-analyses have shown contrast-enhanced ultrasound (CEUS) to be a good alternative. The main goal of our study was to further validate the inclusion of CEUS in follow-up examination protocols for the systematic surveillance after EVAR. METHODS: A retrospective analysis of patients who had received CEUS as part of their routine surveillance after EVAR at our center was conducted. Detection rate and classification of endoleak types were compared between available postinterventional CTA/magnetic resonance angiography and follow-up CEUS examinations. Last preinterventional CTAs before EVAR served as baselines with focus on potential cofactors such as age, body mass index, maximum aortic aneurysm diameters, endoleak orientation, and distance-to-surface influencing detection rates and classification. RESULTS: In total, 101 patients were included in the analysis. Forty-four endoleaks (43.5% of cases) were detected by either initial CEUS or CTA, mostly type II (37.6% of the included patients). Initial CEUS showed an endoleak sensitivity of 91.2%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 84.6%. No covariate with an influence on the correct classification could be identified either for CEUS or CT. CONCLUSIONS: CEUS should be considered a valid complementary method to CTA in the lifelong surveillance after EVAR. As type II endoleaks seem to be a common early-term, sometimes spontaneously resolving complication that can potentially be missed by CTA, we suggest combined follow-up protocols including CEUS in the early on postinterventional assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Medical University Innsbruck, Innsbruck, Austria.
- Department of Radiology, Medical University Innsbruck, Innsbruck, Austria. Electronic address: Leonhard.gruber@i-med.ac.at.
- Department of Vascular Surgery, Medical University Innsbruck, Innsbruck, Austria.
Zitieren
APA
Morell-Hofert, D., Gruber, L., Gruber, H., Glodny, B., Gruber, I., & Loizides, A. (2024). Contrast-Enhanced Ultrasound after Endovascular Aortic Repair: Supplement and Potential Substitute for CT in Early- and Long-Term Follow-Up. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2023.11.040
Vancouver
Morell-Hofert D, Gruber L, Gruber H, Glodny B, Gruber I, Loizides A. Contrast-Enhanced Ultrasound after Endovascular Aortic Repair: Supplement and Potential Substitute for CT in Early- and Long-Term Follow-Up. Annals of Vascular Surgery. 2024. doi:10.1016/j.avsg.2023.11.040
BibTeX
@article{MorellHofert2024,
author = {Morell-Hofert, Dagmar and Gruber, Leonhard and Gruber, Hannes and Glodny, Bernhard and Gruber, Ingrid and Loizides, Alexander},
title = {Contrast-Enhanced Ultrasound after Endovascular Aortic Repair: Supplement and Potential Substitute for CT in Early- and Long-Term Follow-Up},
journal = {Annals of Vascular Surgery},
year = {2024},
doi = {10.1016/j.avsg.2023.11.040}
}
EUVIMED