Educational utility of a 3D-printed canine hepatic artery phantom for CT bolus tracking training
Alternatives to Laboratory Animals · 2026-11 · 54 (6) · 315-325
DOI: 10.1177/02611929261489758 ↗Kurz gefasst
Fachartikel in der Zeitschrift Alternatives to Laboratory Animals, online erschienen am 21.09.2026. Verfasst von Keonyeong Min und 2 weiteren Autor:innen. Beteiligte Einrichtung: Section of Veterinary Medical Imaging, Veterinary Medical Center, Chungbuk National University, Cheongju, Korea. Die Arbeit nennt 17 Literaturangaben. Gefördert von: Chungbuk National University NUDP program, National Research Foundation of Korea (NRF) grant funded by the Korea government, Ministry of Agriculture, Food and Rural Affairs.
Abstract (Originalsprache)
Computed tomography angiography (CTA) is critical for evaluating abdominal diseases in veterinary patients. However, mastering bolus tracking remains a challenge for novice trainees, due to its steep learning curve and narrow temporal window. We evaluated the effectiveness of a 3D-printed canine hepatic artery phantom as a simulator-based training tool to improve technical proficiency in CT bolus tracking. The phantom was integrated into a closed-loop circuit with a peristaltic pump to replicate physiologic contrast kinetics. Eighteen participants, who were stratified by level of experience (A, experienced; B, intermediate; C, beginner), completed three repeated trials of a standardised bolus tracking protocol. Training efficacy was assessed by using objective timing metrics, and subjective pre- and post-training evaluations and subjective Likert scale-based questionnaires. Total operation time significantly decreased in Groups B and C, while Group A showed a non-significant reduction. Significant improvements in region of interest (ROI) placement time were observed across all groups. Furthermore, participants reported significant increases in conceptual understanding, procedural confidence and anatomical recognition. Use of the 3D-printed canine hepatic artery phantom is a feasible ethical alternative to the use of animals for such training purposes, effectively standardising technical proficiency in veterinary radiology. The study findings support the integration of high-fidelity phantom use into veterinary radiology curricula, to bridge the gap between theory and clinical practice.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Section of Veterinary Medical Imaging, Veterinary Medical Center, Chungbuk National University, Cheongju, Korea.
ORCID-Profile: Namsoon Lee
Förderung
- Chungbuk National University NUDP program
- National Research Foundation of Korea (NRF) grant funded by the Korea government
- Ministry of Agriculture, Food and Rural Affairs
Zitieren
APA
Min, K., Chang, D., & Lee, N. (2026). Educational utility of a 3D-printed canine hepatic artery phantom for CT bolus tracking training. Alternatives to Laboratory Animals, 54(6), 315-325. https://doi.org/10.1177/02611929261489758
Vancouver
Min K, Chang D, Lee N. Educational utility of a 3D-printed canine hepatic artery phantom for CT bolus tracking training. Alternatives to Laboratory Animals. 2026;54(6):315-325. doi:10.1177/02611929261489758
BibTeX
@article{Min2026,
author = {Min, Keonyeong and Chang, Dongwoo and Lee, Namsoon},
title = {Educational utility of a 3D-printed canine hepatic artery phantom for CT bolus tracking training},
journal = {Alternatives to Laboratory Animals},
year = {2026},
volume = {54},
number = {6},
pages = {315--325},
doi = {10.1177/02611929261489758}
}
EUVIMED