Introduction

Surgical simulators are designed to improve operative skills and patient safety. Total hip replacement (THR) in veterinary medicine is a relatively challenging surgery with a slow learning curve. A reusable and customizable 3-dimensional (3D)-printed THR surgery simulator may facilitate the development of surgical skills in a safe and low-stress environment. This pilot study aims to design, fabricate, and test a low-cost and reusable 3D-printed THR simulator for acetabular cup implantation. Materials and Methods: The acetabular cup simulator was designed based on the CT scan of four dogs with four different pathological stages (normal, mild, moderate, and severe). The simulators were fabricated to simulate the difficult aspects of acetabular preparation and implantation, such as ventral soft tissue tension. One experienced surgeon performed acetabular preparation and cup implantation on four different simulators. The time to complete each simulator and the accuracy of acetabular cup positioning were measured. Reaming and cup insertion time were separately measured. Acetabular cup insertion was evaluated by angles of lateral opening, retroversion, and inclination.

Results

Surgical times (reaming/cup insertion) were 109/60, 180/29, 210/141, and 156/92 seconds in the normal, mild, moderate, and severe hip models, respectively. Cupt placement values (opening/retroversion/inclination) were 37/12/32, 41/10/35, 34/14/25, and 48/9/19 in the normal, mild, moderate, and severe hip models, respectively; all these parameters were within acceptable ranges. Discussion/Conclusion: We describe the early development of a novel 3D-printed model for the training of total hip replacement. Given that various hip joint models with different dysplastic stages can be designed and soft tissue resistance can be simulated, this surgical simulator may be an affordable and realistic alternative to traditional cadaveric surgical simulation. Further studies with more surgeons are underway. Acknowledgements: There was no proprietary interest or funding provided for this project. Publication History Article published online: 16 September 2024 Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Kim, M., & Kim, S. (2024). Development of a 3D-Printed Canine Hip Dysplastic Model for Acetabular Cup Implantation Training. Veterinary and Comparative Orthopaedics and Traumatology, 37(05), S111-S142. https://doi.org/10.1055/s-0044-1791349

Vancouver

Kim M, Kim S. Development of a 3D-Printed Canine Hip Dysplastic Model for Acetabular Cup Implantation Training. Veterinary and Comparative Orthopaedics and Traumatology. 2024;37(05):S111-S142. doi:10.1055/s-0044-1791349

BibTeX
@article{Kim2024,
  author = {Kim, M.-Y. and Kim, S.},
  title = {Development of a 3D-Printed Canine Hip Dysplastic Model for Acetabular Cup Implantation Training},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2024},
  volume = {37},
  number = {05},
  pages = {S111--S142},
  doi = {10.1055/s-0044-1791349}
}