EUVIMEDEUVIMED entdecken
Crossref

Toward Real-Time GPU Implementation of Diverging Beam With Synthetic Aperture Technique With Non-linear Beamforming for a Curvilinear Array

Lokesh Basavarajappa iD, Rahul R iD, R Tushar, Arun K Thittai

Ultrasonic Imaging · 2025

DOI: 10.1177/01617346251406540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, 2025. Verfasst von Lokesh Basavarajappa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Mehta family school of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, Madhya Pradesh, India. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Computer Graphics. Die Arbeit nennt 31 Literaturangaben. Gefördert von: The Center for Sports Science and Analytics, IIT Madras, Science and Engineering Board, Government of India, Corporate social responsibility grant to the Biomedical Ultrasound Lab, IIT Madras.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional focused ultrasound imaging typically utilizes focused transmit beams in conjunction with a delay-and-sum (DAS) beamformer for reception, which yields optimal image quality only within the focal zone. To overcome this limitation, synthetic transmit aperture (STA) techniques and advanced non-linear beamforming methods are being explored to enhance the quality of ultrasound images. However, implementing these two approaches demands substantial computational resources. Although ultrasound systems utilizing GPU technology have demonstrated potential for real-time processing, their practical application is still limited. Real-time and affordable systems utilizing STA imaging and advanced non-linear beamforming are still not common in practical applications. Furthermore, the use of curvilinear array transducers is yet largely unexplored in the context of STA imaging. In this study, we present a GPU-based real-time affordable system for curvilinear array transducers that employs diverging beam with synthetic transmit aperture technique (DBSAT) imaging with non-linear beamforming. Experimental RF data were acquired using a tissue-mimicking phantom (CIRS Model 040GSE) with a DBSAT and conventional focused beamforming (CFB) sequence implemented on the programmable Verasonics Vantage 64 system equipped with a C5-2 curvilinear array probe. Beamforming was performed using an NVIDIA GeForce RTX 3060 GPU, implementing both DAS and filtered delay multiply and sum (FDMAS) algorithms. The results suggest that DBSAT-FDMAS using a curvilinear transducer yields improved image quality when the virtual source is positioned closer to the transducer, compared to an infinite virtual source distance. Further, reducing the number of receive elements has a minimal effect on image quality. The estimated axial and lateral resolutions for CFB-FDMAS range from 0.56 to 0.86 mm and 0.39 to 0.96 mm, respectively, whereas for DBSAT32-FDMAS, they range from 0.62 to 0.93 mm and 0.30 to 0.79 mm, respectively. The estimated CNR and gCNR values for CFB-FDMAS are 1.34 and 0.78, respectively, while those for DBSAT32-FDMAS are 1.84 and 0.81, respectively. In summary, DBSAT-FDMAS using 32 active receive elements offers enhanced image quality compared to CFB-FDMAS, while maintaining similar execution times.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedSignal Processing, Computer-AssistedComputer GraphicsUltrasonographyPhantoms, ImagingTransducersAlgorithmsEquipment DesignParallel AlgorithmsComputer Systems

Stichwörter der Autor:innen

Graphics processing unit (GPU)curvilinear array transducerfiltered delay multiply and sum (FDMAS)synthetic transmit aperture (STA)ultrasound

Autor:innen und Institutionen

  • Mehta family school of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, Madhya Pradesh, India.
  • Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India.

ORCID-Profile: Lokesh Basavarajappa, Rahul R

Förderung

  • The Center for Sports Science and Analytics, IIT Madras
  • Science and Engineering Board, Government of India
  • Corporate social responsibility grant to the Biomedical Ultrasound Lab, IIT Madras

Zitieren

APA

Basavarajappa, L., R, R., Tushar, R., & Thittai, A. K. (2025). Toward Real-Time GPU Implementation of Diverging Beam With Synthetic Aperture Technique With Non-linear Beamforming for a Curvilinear Array. Ultrasonic Imaging. https://doi.org/10.1177/01617346251406540

Vancouver

Basavarajappa L, R R, Tushar R, Thittai AK. Toward Real-Time GPU Implementation of Diverging Beam With Synthetic Aperture Technique With Non-linear Beamforming for a Curvilinear Array. Ultrasonic Imaging. 2025. doi:10.1177/01617346251406540

BibTeX
@article{Basavarajappa2025,
  author = {Basavarajappa, Lokesh and R, Rahul and Tushar, R and Thittai, Arun K},
  title = {Toward Real-Time GPU Implementation of Diverging Beam With Synthetic Aperture Technique With Non-linear Beamforming for a Curvilinear Array},
  journal = {Ultrasonic Imaging},
  year = {2025},
  doi = {10.1177/01617346251406540}
}
Kostenlos starten →