EUVIMEDEUVIMED entdecken
Crossref

Computational Ultrasound Carotid Artery Imaging With a Few Transceivers: An Emulation Study

Yuyang Hu, Didem Dogan, Michael Brown, Geert Leus, Antonius F W van der Steen, Pieter Kruizinga, Johannes G Bosch

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2025

DOI: 10.1109/tuffc.2025.3557374 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2025. Verfasst von Yuyang Hu und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Carotid Arteries, Image Processing, Computer-Assisted. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Open Technology Programme (OTP) Three-dimensional Ultrasound Imaging Through Compressive Spatial Coding (TOUCAN) under Project, Dutch Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasonography could allow operator-independent examination and continuous monitoring of the carotid artery (CA) but normally requires complex and expensive transducers, especially for 3-D. By employing computational ultrasound imaging (cUSi), using an aberration mask and model-based reconstruction, a monitoring device could be constructed with a more affordable simple transducer design comprising only a few elements. We aim to apply the cUSi concept to create a CA monitoring system. The system's possible configurations for the 2-D imaging case were explored using a linear array setup emulating a cUSi device in silico, followed by in vitro testing and in vivo CA imaging. Our study shows enhanced reconstruction performance with the use of an aberrating mask, improved lateral resolution through proper choice of the mask delay variation, and more accurate reconstructions using least-squares with QR (LSQR) decomposition compared to matched filtering (MF). Together, these advancements enable B-mode reconstruction and power Doppler imaging (PDI) of the CA with sufficient quality for monitoring using a configuration of 12 transceivers coupled with a random aberration mask with a maximum delay variation of four wave periods (WPs).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carotid ArteriesImage Processing, Computer-AssistedUltrasonographyPhantoms, ImagingHumansTransducersComputer SimulationAlgorithmsEquipment Design

Förderung

  • Open Technology Programme (OTP) Three-dimensional Ultrasound Imaging Through Compressive Spatial Coding (TOUCAN) under Project
  • Dutch Research Council

Zitieren

APA

Hu, Y., Dogan, D., Brown, M., Leus, G., van der Steen, A. F. W., Kruizinga, P., & Bosch, J. G. (2025). Computational Ultrasound Carotid Artery Imaging With a Few Transceivers: An Emulation Study. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2025.3557374

Vancouver

Hu Y, Dogan D, Brown M, Leus G, van der Steen AFW, Kruizinga P, et al. Computational Ultrasound Carotid Artery Imaging With a Few Transceivers: An Emulation Study. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2025. doi:10.1109/tuffc.2025.3557374

BibTeX
@article{Hu2025,
  author = {Hu, Yuyang and Dogan, Didem and Brown, Michael and Leus, Geert and van der Steen, Antonius F W and Kruizinga, Pieter and Bosch, Johannes G},
  title = {Computational Ultrasound Carotid Artery Imaging With a Few Transceivers: An Emulation Study},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2025},
  doi = {10.1109/tuffc.2025.3557374}
}
Kostenlos starten →