Visual Acuity Prediction Based on Different Refraction Types For Patients With Down Syndrome
Translational Vision Science & Technology · 19.09.2023 · 12 (9) · 11
DOI: 10.1167/tvst.12.9.11 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 19.09.2023. Verfasst von Lauren V Schneider und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Ohio State University College of Optometry, Columbus, Ohio, USA. Hauptthemen laut MEDLINE: Down Syndrome. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
The purpose of this study was to determine if control observers can be used as surrogates to predict visual acuity (VA) of patients with Down syndrome (DS).
Methods
Thirty adults with DS were enrolled in a clinical trial testing three refraction types: clinical refraction and two using wavefront aberration measures to optimize the metrics pupil fraction tessellated (PFSt) and visual Strehl ratio (VSX). Monocular VA was obtained through habitual refractions and each experimental refraction type. Five controls without DS viewed acuity charts simulating the retinal image produced when the corrections for each DS eye are worn, performing VA and scoring image quality of each chart. Group median VA (DS versus controls) were compared for each refraction type, and control image quality scores were compared to corresponding VA across refraction types.
Results
Median VA for participants with DS ranged from 0.46 logMAR (interquartile range [IQR] = 0.32 to 0.54) with habitual correction to 0.36 logMAR (IQR = 0.28 to 0.54) with VSX, whereas controls ranged from 0.37 logMAR (IQR = 0.29 to 0.42) with habitual correction to 0.01 logMAR (IQR = -0.02 to 0.05) with VSX. Overall image quality scores were best for PFSt and VSX and showed a strong linear relationship with control VA (r = -0.91, P < 0.001), and a lesser correlation with DS VA (r = -0.33, P < 0.001).
Conclusions
Using surrogate observers to judge image quality simulations of eyes with DS did not predict actual VA, suggesting additional, non-optical factors may be limiting VA in individuals with DS. Translational Relevance: Findings may guide clinical refraction practices for patients with DS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- The Ohio State University College of Optometry, Columbus, Ohio, USA.
- University of Houston, College of Optometry, Houston, Texas, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Schneider, L. V., Mitchell, G. L., Marsack, J. D., & Anderson, H. A. (2023). Visual Acuity Prediction Based on Different Refraction Types For Patients With Down Syndrome. Translational Vision Science & Technology, 12(9), 11. https://doi.org/10.1167/tvst.12.9.11
Vancouver
Schneider LV, Mitchell GL, Marsack JD, Anderson HA. Visual Acuity Prediction Based on Different Refraction Types For Patients With Down Syndrome. Translational Vision Science & Technology. 2023;12(9):11. doi:10.1167/tvst.12.9.11
BibTeX
@article{Schneider2023,
author = {Schneider, Lauren V and Mitchell, G Lynn and Marsack, Jason D and Anderson, Heather A},