EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Evaluating the visual benefits of toric soft contact lenses using a novel pupil-controlled vision testing system

Michael Read, Philip Morgan, Carole Maldonado-Codina, Gary Orsborn, Jose Vega, Maria Navascues-Cornago

Contact Lens and Anterior Eye · 2025

DOI: 10.1016/j.clae.2025.102604 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Contact Lens and Anterior Eye, 2025. Verfasst von Michael Read und 5 weiteren Autor:innen. Beteiligte Einrichtung: Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK. Electro…. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Visual Acuity, Astigmatism, Pupil. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CooperVision.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study investigated the clinical astigmatism threshold at which toric soft contact lenses (CLs) provide superior visual acuity (VA) compared with spherical CLs, and how pupil size affects this. A novel pupil-controlled vision testing system (PUCS) was developed to assess VA across different pupil sizes by dynamically adjusting lighting conditions. METHODS: A randomised, crossover, partially participant-masked clinical study was conducted with 53 habitual soft CL wearers (84 eyes; ages 20-40). Eyes were categorised into seven astigmatism groups (0.00 to -1.50 DC in 0.25 DC steps). Each eye was tested with three corrections: spherical soft CLs, custom toric soft CLs, and full-correction spectacles. VA was assessed using PUCS at five pupil diameters (2.5 mm, 4.0 mm, 5.5 mm, maximum, and minimum). The primary outcome was the between-correction difference in PUCS logMAR visual acuity, assessed at each pupil diameter. Secondary measures included conventional VA, subjective ratings, and lens preference. RESULTS: PUCS VA decreased significantly with increasing pupil diameter across all corrections (p< 0.0001). Toric CLs provided significantly better PUCS VA than spherical CLs for astigmatism of -0.75 DC and greater, regardless of pupil diameter (p< 0.001). The mean toric-spherical difference was approximately 0.06 logMAR (≈3 letters) at -0.75 DC and 0.12 logMAR (≈6 letters) at -1.50 DC. Toric CL performance was comparable to spectacle correction across all cylinder groups. Participants favoured toric CLs over spherical lenses from -0.75 DC upwards, with no participants preferring spherical CLs at -1.25 DC or greater (p< 0.001). Toric CLs demonstrated excellent rotational stability. CONCLUSIONS: The PUCS system provided robust evidence that toric CLs offer significant visual benefits at -0.75 DC or greater (within the tested range up to -1.50 DC), irrespective of pupil diameter. These findings support routine soft toric CL prescribing for astigmatism correction at or above this threshold to optimise visual performance and patient satisfaction. CLINICAL TRIAL REGISTRATION: This study was registered at ClinicalTrials.gov (Identifier: NCT04613882).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contact Lenses, HydrophilicVisual AcuityAstigmatismPupilVision TestsHumansFemaleAdultMaleYoung AdultCross-Over StudiesEquipment DesignTreatment OutcomeEquipment Failure AnalysisReproducibility of Results

Stichwörter der Autor:innen

AstigmatismPupil sizePupil-controlled vision testing system (PUCS)Subjective visual qualityToric soft contact lensesVisual acuity

Autor:innen und Institutionen

  • Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK. Electronic address: michael.read-3@manchester.ac.uk.
  • Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK.
  • CooperVision Inc., San Ramon, CA, USA.

Förderung

  • CooperVision

Zitieren

APA

Read, M., Morgan, P., Maldonado-Codina, C., Orsborn, G., Vega, J., & Navascues-Cornago, M. (2025). Evaluating the visual benefits of toric soft contact lenses using a novel pupil-controlled vision testing system. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2025.102604

Vancouver

Read M, Morgan P, Maldonado-Codina C, Orsborn G, Vega J, Navascues-Cornago M. Evaluating the visual benefits of toric soft contact lenses using a novel pupil-controlled vision testing system. Contact Lens and Anterior Eye. 2025. doi:10.1016/j.clae.2025.102604

BibTeX
@article{Read2025,
  author = {Read, Michael and Morgan, Philip and Maldonado-Codina, Carole and Orsborn, Gary and Vega, Jose and Navascues-Cornago, Maria},
  title = {Evaluating the visual benefits of toric soft contact lenses using a novel pupil-controlled vision testing system},
  journal = {Contact Lens and Anterior Eye},
  year = {2025},
  doi = {10.1016/j.clae.2025.102604}
}
Kostenlos starten →