Dioptric differences between clinically determined and metric‐optimised refractions for adults with Down syndrome
Ophthalmic and Physiological Optics · 2023
DOI: 10.1111/opo.13165 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2023. Verfasst von Maureen D Plaumann und 4 weiteren Autor:innen. Beteiligte Einrichtung: University of Houston College of Optometry, Houston, Texas, USA. Hauptthemen laut MEDLINE: Down Syndrome, Refractive Errors, Myopia. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, National Eye Institute.
Abstract (Originalsprache)
Purpose
Refractions based on the optimisation of single‐value wavefront‐derived metrics may help determine appropriate corrections for individuals with Down syndrome where clinical techniques fall short. This study compared dioptric differences between refractions obtained using standard clinical techniques and two metric‐optimised methods: visual Strehl ratio (VSX) and pupil fraction tessellated (PFSt), and investigated characteristics that may contribute to the differences between refraction types.
Methods
Thirty adults with Down syndrome (age = 29 ± 10 years) participated. Three refractive corrections (VSX, PFSt and clinical) were determined and converted to vector notation (M, J 0 , J 45 ) to calculate the dioptric difference between pairings of each type using a mixed model repeated measures approach. Linear correlations and multivariable regression were performed to examine the relationship between dioptric differences and the following participant characteristics: higher order root mean square (RMS) for a 4 mm pupil diameter, spherical equivalent refractive error and Vineland Adaptive Behavior Scales (a measure of developmental ability).
Results
The least squares mean estimates (standard error) of the dioptric differences for each pairing were as follows: VSX versus PFSt = 0.51 D (0.11); VSX versus clinical = 1.19 D (0.11) and PFSt versus clinical = 1.04 D (0.11). There was a statistically significant difference in the dioptric differences between the clinical refraction and each of the metric‐optimised refractions ( p < 0.001). Increased dioptric differences in refraction were correlated with increased higher order RMS ( R = 0.64, p < 0.001 [VSX vs. clinical] and R = 0.47, p < 0.001 [PFSt vs. clinical]) as well as increased myopic spherical equivalent refractive error ( R = 0.37, p = 0.004 [VSX vs. clinical] and R = 0.51, p < 0.001 [PFSt vs. clinical]).
Conclusions
The observed differences in refraction demonstrate that a significant portion of the refractive uncertainty is related to increased higher order aberrations and myopic refractive error. Methodology surrounding clinical techniques and metric‐optimisation based on wavefront aberrometry may explain the difference in refractive endpoints.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Houston College of Optometry, Houston, Texas, USA.
- Texas Institute for Measurement, Evaluation, and Statistics, Houston, Texas, USA.
- The Ohio State University College of Optometry, Columbus, Ohio, USA.
ORCID-Profile: Maureen D Plaumann, Jason D Marsack, Heather A Anderson
Förderung
- NEI NIH HHS
- National Eye Institute
Zitieren
APA
Plaumann, M. D., Marsack, J. D., Benoit, J. S., Manny, R. E., & Anderson, H. A. (2023). Dioptric differences between clinically determined and metric‐optimised refractions for adults with Down syndrome. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13165
Vancouver
Plaumann MD, Marsack JD, Benoit JS, Manny RE, Anderson HA. Dioptric differences between clinically determined and metric‐optimised refractions for adults with Down syndrome. Ophthalmic and Physiological Optics. 2023. doi:10.1111/opo.13165
BibTeX
@article{Plaumann2023,
author = {Plaumann, Maureen D and Marsack, Jason D and Benoit, Julia S and Manny, Ruth E and Anderson, Heather A},
title = {Dioptric differences between clinically determined and metric‐optimised refractions for adults with Down syndrome},
journal = {Ophthalmic and Physiological Optics},
year = {2023},
doi = {10.1111/opo.13165}
}
EUVIMED