EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study

Yingxiang Han, Xiaofei Wang, Can Can Xue, Jost B Jonas, Ya Xing Wang

Investigative Ophthalmology & Visual Science · 2024-07-18 · 65 (8) · 28

DOI: 10.1167/iovs.65.8.28 ↗

At a glance

Journal article in Investigative Ophthalmology & Visual Science, published on 2024-07-18. Written by Yingxiang Han and 4 co-authors. Institution: Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Bio…. Major MEDLINE topics: Tomography, Optical Coherence, Optic Disk, Myopia, Degenerative. Cited 4 times so far (Crossref); 47 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The purpose of this study was to examine characteristics of lamina cribrosa (LC) configuration in highly myopic (HM) eyes.

Methods

Participants from the Beijing Eye Study 2011, free of optic nerve or retinal diseases, were randomly selected to examine LC depth (LCD) and LC tilt (LCT) using three-dimensional optical coherent tomography images of the optic nerve head (ONH). LCD and LCT were measured as the distance and angle between the LC plane with two reference planes, including the Bruch's membrane opening (BMO) plane and the peripapillary sclera (PPS) plane, respectively. Each parameter was measured in both horizontal and vertical B-scans.

Results

The study included 685 individuals (685 eyes) aged 59.6 ± 7.7 years, including 72 HM eyes and 613 non-HM eyes. LCD measurements showed no significant differences between HM eyes and non-HM eyes in both horizontal (LCD-BMO = 421.83 ± 107.86 µm for HM eyes vs. 447.24 ± 104.94 µm for non-HM eyes, P = 0.18; and LCD-PPS = 406.39 ± 127.69 µm vs. 394.00 ± 101.64 µm, P = 1.00) and vertical directions (LCD-BMO = 435.78 ± 101.29 µm vs. 450.97 ± 106.54 µm, P = 0.70; and LCD-PPS = 401.62 ± 109.9 µm vs. 379.85 ± 110.35 µm, P = 0.35). However, the LCT was significantly more negative (tilted) in HM eyes than in non-HM eyes horizontally (LCT-BMO = -4.38 ± 5.94 degrees vs. -0.04 ± 5.86 degrees, P < 0.001; and LCT-PPS = -3.16 ± 5.23 degrees vs. -0.94 ± 4.71 degrees, P = 0.003), but not vertically (P = 1.00).

Conclusions

Although LCD did not differ significantly between HM and non-HM eyes, LCT was more negative in HM eyes, suggesting that the temporal or inferior side of the LC was closer to the reference plane. These findings provide insights into morphological and structural changes in the LC and ONH between HM and non-HM eyes.

Subjects

MeSH terms (MEDLINE)

Tomography, Optical CoherenceOptic DiskMyopia, DegenerativeHumansMiddle AgedMaleFemaleAgedImaging, Three-DimensionalBeijingBruch MembraneCross-Sectional StudiesChinaMyopiaSclera

Authors and institutions

  • Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing,…
  • Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.
  • Rothschild Foundation Hospital, Institut Français de Myopie, Paris, France.
  • Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.

Cite

APA

Han, Y., Wang, X., Xue, C. C., Jonas, J. B., & Wang, Y. X. (2024). Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study. Investigative Ophthalmology & Visual Science, 65(8), 28. https://doi.org/10.1167/iovs.65.8.28

Vancouver

Han Y, Wang X, Xue CC, Jonas JB, Wang YX. Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study. Investigative Ophthalmology & Visual Science. 2024;65(8):28. doi:10.1167/iovs.65.8.28

BibTeX
@article{Han2024,
  author = {Han, Yingxiang and Wang, Xiaofei and Xue, Can Can and Jonas, Jost B and Wang, Ya Xing},
  title = {Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2024},
  volume = {65},
  number = {8},
  pages = {28},
  doi = {10.1167/iovs.65.8.28}
}
Start for free →