Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study
Investigative Ophthalmology & Visual Science · 2024-07-18 · 65 (8) · 28
DOI: 10.1167/iovs.65.8.28 ↗At a glance
Journal article in Investigative Ophthalmology & Visual Science, published on 2024-07-18. Written by Yingxiang Han and 4 co-authors. Institution: Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Bio…. Major MEDLINE topics: Tomography, Optical Coherence, Optic Disk, Myopia, Degenerative. Cited 4 times so far (Crossref); 47 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Purpose
The purpose of this study was to examine characteristics of lamina cribrosa (LC) configuration in highly myopic (HM) eyes.
Methods
Participants from the Beijing Eye Study 2011, free of optic nerve or retinal diseases, were randomly selected to examine LC depth (LCD) and LC tilt (LCT) using three-dimensional optical coherent tomography images of the optic nerve head (ONH). LCD and LCT were measured as the distance and angle between the LC plane with two reference planes, including the Bruch's membrane opening (BMO) plane and the peripapillary sclera (PPS) plane, respectively. Each parameter was measured in both horizontal and vertical B-scans.
Results
The study included 685 individuals (685 eyes) aged 59.6 ± 7.7 years, including 72 HM eyes and 613 non-HM eyes. LCD measurements showed no significant differences between HM eyes and non-HM eyes in both horizontal (LCD-BMO = 421.83 ± 107.86 µm for HM eyes vs. 447.24 ± 104.94 µm for non-HM eyes, P = 0.18; and LCD-PPS = 406.39 ± 127.69 µm vs. 394.00 ± 101.64 µm, P = 1.00) and vertical directions (LCD-BMO = 435.78 ± 101.29 µm vs. 450.97 ± 106.54 µm, P = 0.70; and LCD-PPS = 401.62 ± 109.9 µm vs. 379.85 ± 110.35 µm, P = 0.35). However, the LCT was significantly more negative (tilted) in HM eyes than in non-HM eyes horizontally (LCT-BMO = -4.38 ± 5.94 degrees vs. -0.04 ± 5.86 degrees, P < 0.001; and LCT-PPS = -3.16 ± 5.23 degrees vs. -0.94 ± 4.71 degrees, P = 0.003), but not vertically (P = 1.00).
Conclusions
Although LCD did not differ significantly between HM and non-HM eyes, LCT was more negative in HM eyes, suggesting that the temporal or inferior side of the LC was closer to the reference plane. These findings provide insights into morphological and structural changes in the LC and ONH between HM and non-HM eyes.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing,…
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.
- Rothschild Foundation Hospital, Institut Français de Myopie, Paris, France.
- Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.
Cite
APA
Han, Y., Wang, X., Xue, C. C., Jonas, J. B., & Wang, Y. X. (2024). Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study. Investigative Ophthalmology & Visual Science, 65(8), 28. https://doi.org/10.1167/iovs.65.8.28
Vancouver
Han Y, Wang X, Xue CC, Jonas JB, Wang YX. Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study. Investigative Ophthalmology & Visual Science. 2024;65(8):28. doi:10.1167/iovs.65.8.28
BibTeX
@article{Han2024,
author = {Han, Yingxiang and Wang, Xiaofei and Xue, Can Can and Jonas, Jost B and Wang, Ya Xing},
title = {Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study},
journal = {Investigative Ophthalmology & Visual Science},
year = {2024},
volume = {65},
number = {8},
pages = {28},
doi = {10.1167/iovs.65.8.28}
}
EUVIMED