Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography
Investigative Ophthalmology & Visual Science · 2024
DOI: 10.1167/iovs.65.6.6 ↗At a glance
Journal article in Investigative Ophthalmology & Visual Science, 2024. Written by Justin Engelmann and 15 co-authors. Institution: School of Informatics, University of Edinburgh, Edinburgh, United Kingdom. Major MEDLINE topics: Choroid, Tomography, Optical Coherence. Cited 14 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: Wellcome Trust, Medical Research Council.
Abstract (original language)
Purpose
To develop Choroidalyzer, an open-source, end-to-end pipeline for segmenting the choroid region, vessels, and fovea, and deriving choroidal thickness, area, and vascular index.
Methods
We used 5600 OCT B-scans (233 subjects, six systemic disease cohorts, three device types, two manufacturers). To generate region and vessel ground-truths, we used state-of-the-art automatic methods following manual correction of inaccurate segmentations, with foveal positions manually annotated. We trained a U-Net deep learning model to detect the region, vessels, and fovea to calculate choroid thickness, area, and vascular index in a fovea-centered region of interest. We analyzed segmentation agreement (AUC, Dice) and choroid metrics agreement (Pearson, Spearman, mean absolute error [MAE]) in internal and external test sets. We compared Choroidalyzer to two manual graders on a small subset of external test images and examined cases of high error.
Results
Choroidalyzer took 0.299 seconds per image on a standard laptop and achieved excellent region (Dice: internal 0.9789, external 0.9749), very good vessel segmentation performance (Dice: internal 0.8817, external 0.8703), and excellent fovea location prediction (MAE: internal 3.9 pixels, external 3.4 pixels). For thickness, area, and vascular index, Pearson correlations were 0.9754, 0.9815, and 0.8285 (internal)/0.9831, 0.9779, 0.7948 (external), respectively (all P < 0.0001). Choroidalyzer's agreement with graders was comparable to the intergrader agreement across all metrics.
Conclusions
Choroidalyzer is an open-source, end-to-end pipeline that accurately segments the choroid and reliably extracts thickness, area, and vascular index. Especially choroidal vessel segmentation is a difficult and subjective task, and fully automatic methods like Choroidalyzer could provide objectivity and standardization.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- School of Informatics, University of Edinburgh, Edinburgh, United Kingdom.
- Centre for Medical Informatics, University of Edinburgh, Edinburgh, United Kingdom.
- School of Mathematics, University of Edinburgh, Edinburgh, United Kingdom.
- Clinical Research Facility and Imaging, University of Edinburgh, Edinburgh, United Kingdom.
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom.
- Department of Vision Sciences, Glasgow Caledonian University, Glasgow, United Kingdom.
Funding
- Wellcome Trust
- Medical Research Council
Cite
APA
Engelmann, J., Burke, J., Hamid, C., Reid-Schachter, M., Pugh, D., Dhaun, N., Moukaddem, D., Gray, L., Strang, N., McGraw, P., Storkey, A., Steptoe, P. J., King, S., MacGillivray, T., Bernabeu, M. O., & MacCormick, I. J. C. (2024). Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.6.6
Vancouver
Engelmann J, Burke J, Hamid C, Reid-Schachter M, Pugh D, Dhaun N, et al. Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.6.6
BibTeX
@article{Engelmann2024,
author = {Engelmann, Justin and Burke, Jamie and Hamid, Charlene and Reid-Schachter, Megan and Pugh, Dan and Dhaun, Neeraj and Moukaddem, Diana and Gray, Lyle and Strang, Niall and McGraw, Paul and Storkey, Amos and Steptoe, Paul J and King, Stuart and MacGillivray, Tom and Bernabeu, Miguel O and MacCormick, Ian J C},
title = {Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography},
journal = {Investigative Ophthalmology & Visual Science},
year = {2024},
doi = {10.1167/iovs.65.6.6}
}
EUVIMED