At a glance

Journal article in Investigative Ophthalmology & Visual Science, 2024. Written by Justin Engelmann and 15 co-authors. Institution: School of Informatics, University of Edinburgh, Edinburgh, United Kingdom. Major MEDLINE topics: Choroid, Tomography, Optical Coherence. Cited 14 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: Wellcome Trust, Medical Research Council.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To develop Choroidalyzer, an open-source, end-to-end pipeline for segmenting the choroid region, vessels, and fovea, and deriving choroidal thickness, area, and vascular index.

Methods

We used 5600 OCT B-scans (233 subjects, six systemic disease cohorts, three device types, two manufacturers). To generate region and vessel ground-truths, we used state-of-the-art automatic methods following manual correction of inaccurate segmentations, with foveal positions manually annotated. We trained a U-Net deep learning model to detect the region, vessels, and fovea to calculate choroid thickness, area, and vascular index in a fovea-centered region of interest. We analyzed segmentation agreement (AUC, Dice) and choroid metrics agreement (Pearson, Spearman, mean absolute error [MAE]) in internal and external test sets. We compared Choroidalyzer to two manual graders on a small subset of external test images and examined cases of high error.

Results

Choroidalyzer took 0.299 seconds per image on a standard laptop and achieved excellent region (Dice: internal 0.9789, external 0.9749), very good vessel segmentation performance (Dice: internal 0.8817, external 0.8703), and excellent fovea location prediction (MAE: internal 3.9 pixels, external 3.4 pixels). For thickness, area, and vascular index, Pearson correlations were 0.9754, 0.9815, and 0.8285 (internal)/0.9831, 0.9779, 0.7948 (external), respectively (all P < 0.0001). Choroidalyzer's agreement with graders was comparable to the intergrader agreement across all metrics.

Conclusions

Choroidalyzer is an open-source, end-to-end pipeline that accurately segments the choroid and reliably extracts thickness, area, and vascular index. Especially choroidal vessel segmentation is a difficult and subjective task, and fully automatic methods like Choroidalyzer could provide objectivity and standardization.

Subjects

MeSH terms (MEDLINE)

ChoroidTomography, Optical CoherenceHumansMaleFemaleMiddle AgedAgedDeep LearningRetinal VesselsFovea CentralisAdultReproducibility of Results

Authors and institutions

  • School of Informatics, University of Edinburgh, Edinburgh, United Kingdom.
  • Centre for Medical Informatics, University of Edinburgh, Edinburgh, United Kingdom.
  • School of Mathematics, University of Edinburgh, Edinburgh, United Kingdom.
  • Clinical Research Facility and Imaging, University of Edinburgh, Edinburgh, United Kingdom.
  • British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom.
  • Department of Vision Sciences, Glasgow Caledonian University, Glasgow, United Kingdom.

Funding

  • Wellcome Trust
  • Medical Research Council

Cite

APA

Engelmann, J., Burke, J., Hamid, C., Reid-Schachter, M., Pugh, D., Dhaun, N., Moukaddem, D., Gray, L., Strang, N., McGraw, P., Storkey, A., Steptoe, P. J., King, S., MacGillivray, T., Bernabeu, M. O., & MacCormick, I. J. C. (2024). Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.6.6

Vancouver

Engelmann J, Burke J, Hamid C, Reid-Schachter M, Pugh D, Dhaun N, et al. Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.6.6

BibTeX
@article{Engelmann2024,
  author = {Engelmann, Justin and Burke, Jamie and Hamid, Charlene and Reid-Schachter, Megan and Pugh, Dan and Dhaun, Neeraj and Moukaddem, Diana and Gray, Lyle and Strang, Niall and McGraw, Paul and Storkey, Amos and Steptoe, Paul J and King, Stuart and MacGillivray, Tom and Bernabeu, Miguel O and MacCormick, Ian J C},
  title = {Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2024},
  doi = {10.1167/iovs.65.6.6}
}
Start for free →