EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Statistical Model of Ocular Wavefronts With Accommodation

María Mechó-García, María Arcas-Carbonell, Elvira Orduna-Hospital, Ana Sánchez-Cano, Norberto López-Gil, Rute J Macedo-de-Araújo, Miguel Faria-Ribeiro, Paulo Fernandes, José Manuel González-Méijome, Jos Rozema

Investigative Ophthalmology & Visual Science · 2024

DOI: 10.1167/iovs.65.12.12 ↗

At a glance

Journal article in Investigative Ophthalmology & Visual Science, 2024. Written by María Mechó-García and 9 co-authors. Institution: Clinical and Experimental Optometry Research Lab, Physics Center of Minho and Porto Universities (CF-UM-UP), School of Sciences, University of Minho,…. Major MEDLINE topics: Accommodation, Ocular, Corneal Wavefront Aberration, Models, Statistical, Aberrometry. Cited 1 times so far (Crossref); 53 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The purpose of this study was to determine the minimum number of orthonormal basis functions, applying Principal Component Analysis (PCA), to represent the most wavefront aberrations at different accommodation stages. The study also aims to generate synthetic wavefront data using these functions.

Methods

Monocular wavefront data from 191 subjects (26.15 ± 5.56 years old) were measured with a Hartmann-Shack aberrometer, simulating accommodation from 0 diopters (D) to 5 D in 1 D steps. The wavefronts for each accommodative demand were rescaled for different pupil sizes: 4.66, 4.76, 4.40, 4.09, 4.07, and 3.68 mm. PCA was applied to 150 wavefront parameters (25 Zernike coefficients × 6 accommodation levels) to obtain eigenvectors for dimensional reduction. A total of 49 eigenvectors were modeled as a sum of 2 multivariate Gaussians, from which 1000 synthetic data sets were generated.

Results

The first 49 eigenvectors preserved 99.97% of the original data variability. No significant differences were observed between the mean values and standard deviation of the generated and original 49 eigenvectors (two one-sided test [TOST], P > 0.05/49) and (F-test, P > 0.05/49), both with Bonferroni correction. The mean values of the generated parameters (1000) were statistically equal to those of the original data (TOST, P > 0.05/150). The variability of the generated data was similar to the original data for the most important Zernike coefficients (F-test, P > 0.05/150).

Conclusions

PCA significantly reduces the dimensionality of wavefront aberration data across 6 accommodative demands, reducing the variable space by over 66%. The synthetic data generated by the proposed wavefront model for accommodation closely resemble the original clinical data.

Subjects

MeSH terms (MEDLINE)

Accommodation, OcularCorneal Wavefront AberrationModels, StatisticalAberrometryHumansAdultFemaleMaleYoung AdultPrincipal Component AnalysisRefraction, OcularAdolescent

Authors and institutions

  • Clinical and Experimental Optometry Research Lab, Physics Center of Minho and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal.
  • Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España.
  • Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain.
  • Grupo de Ciencias de la Visión (CIVIUM), Universidad de Murcia, Murcia, Spain.
  • Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
  • Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium.

Cite

APA

Mechó-García, M., Arcas-Carbonell, M., Orduna-Hospital, E., Sánchez-Cano, A., López-Gil, N., Macedo-de-Araújo, R. J., Faria-Ribeiro, M., Fernandes, P., González-Méijome, J. M., & Rozema, J. (2024). Statistical Model of Ocular Wavefronts With Accommodation. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.12.12

Vancouver

Mechó-García M, Arcas-Carbonell M, Orduna-Hospital E, Sánchez-Cano A, López-Gil N, Macedo-de-Araújo RJ, et al. Statistical Model of Ocular Wavefronts With Accommodation. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.12.12

BibTeX
@article{MechGarca2024,
  author = {Mechó-García, María and Arcas-Carbonell, María and Orduna-Hospital, Elvira and Sánchez-Cano, Ana and López-Gil, Norberto and Macedo-de-Araújo, Rute J and Faria-Ribeiro, Miguel and Fernandes, Paulo and González-Méijome, José Manuel and Rozema, Jos},
  title = {Statistical Model of Ocular Wavefronts With Accommodation},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2024},
  doi = {10.1167/iovs.65.12.12}
}
Start for free →