Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation
Contact Lens and Anterior Eye · 2024
DOI: 10.1016/j.clae.2024.102133 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von Laura Batres und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry and Vision, Faculty of Optic and Optometry, Complutense University of Madrid, Spain. Hauptthemen laut MEDLINE: Orthokeratologic Procedures, Accommodation, Ocular, Refraction, Ocular, Visual Acuity. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Optometry and Vision, Faculty of Optic and Optometry, Complutense University of Madrid, Spain.
- Department of Optometry and Vision, Faculty of Optic and Optometry, Complutense University of Madrid, Spain. Electronic address: jgcarrac@ucm.es.
Zitieren
APA
Batres, L., Valdes-Soria, G., Romaguera, M., & Carracedo, G. (2024). Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2024.102133
Vancouver
Batres L, Valdes-Soria G, Romaguera M, Carracedo G. Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2024.102133
BibTeX
@article{Batres2024,
author = {Batres, Laura and Valdes-Soria, Gonzalo and Romaguera, María and Carracedo, Gonzalo},
title = {Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation},
journal = {Contact Lens and Anterior Eye},
year = {2024},
doi = {10.1016/j.clae.2024.102133}
}
EUVIMED