Fachartikel in der Zeitschrift Investigative Opthalmology & Visual Science, 2023. Verfasst von Hoi-Lam Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, United States. Hauptthemen laut MEDLINE: Ciliary Body, Anterior Chamber. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the flow pattern in unconventional outflow and its correlation with conventional outflow in mouse eyes.

Methods

Fluorescent microspheres were injected into the anterior chamber of one eye of anesthetized C57BL/6J mice (n = 4), followed by perfused fixation with 4% paraformaldehyde in situ after 45 minutes. Post-euthanasia, the injected eyes were enucleated, further immersion fixed, and dissected into 12 equal radial segments. Both sides of each segment were imaged using a confocal microscope after nuclear counterstaining. Both unconventional and conventional outflow patterns of each eye were analyzed by ImageJ and ZEN 2.3 imaging software.

Results

Segmental outflow patterns were observed in both the ciliary body (CB) and the supraciliary space and suprachoroidal space (SCS). In the CB, the tracer intensity was the lowest at 12 o'clock and highest at 9 o'clock, whereas in the SCS it was the lowest at 2 o'clock and the highest at 10 o'clock. Consequently, a segmental unconventional outflow was observed, with the lowest and highest flow regions in the superior and temporal quadrants, respectively. The overall segmental uveoscleral outflow has no correlation with trabecular outflow (P > 0.05). Four different outflow patterns were observed: (1) low-flow regions in both outflows, (2) primarily a high-flow region in conventional outflow, (3) primarily a high-flow region in unconventional outflow, and (4) high-flow regions in both outflows.

Conclusions

Uveoscleral outflow is segmental and unrelated to the trabecular segmental outflow. These findings will lead to future studies to identify the best location for the placement of drainage devices and drug delivery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ciliary BodyAnterior ChamberMiceAnimalsMice, Inbred C57BLColoring AgentsDrainage

Substanzen

Coloring Agents

Autor:innen und Institutionen

  • Ophthalmology, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, United States.
  • State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Zhejiang, China.
  • Anatomy and Neurobiology, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, United States.

Förderung

  • NEI NIH HHS

Zitieren

APA

Li, H. L., Ren, R., & Gong, H. (2023). Segmental Unconventional Outflow in Mouse Eyes. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.64.15.26

Vancouver

Li HL, Ren R, Gong H. Segmental Unconventional Outflow in Mouse Eyes. Investigative Opthalmology & Visual Science. 2023. doi:10.1167/iovs.64.15.26

BibTeX
@article{Li2023,
  author = {Li, Hoi-Lam and Ren, Ruiyi and Gong, Haiyan},
  title = {Segmental Unconventional Outflow in Mouse Eyes},
  journal = {Investigative Opthalmology & Visual Science},
  year = {2023},
  doi = {10.1167/iovs.64.15.26}
}
Kostenlos starten →