Examining murine eye length asymmetry with spectral domain optical coherence tomography
Experimental Eye Research · 2025
DOI: 10.1016/j.exer.2025.110648 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Eye Research, 2025. Verfasst von Linjiang Lou und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Emory University School of Medicine, 1365B Clifton Rd NE, Atlanta, GA, 30322, United States. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Axial Length, Eye, Myopia, Cornea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: RRD VA, NEI NIH HHS, U.S. Department of Veterans Affairs.
Abstract (Originalsprache)
The mouse is an increasingly popular model for examining refractive development, however measuring axial length in the small mouse eye is challenging. We measured ocular axial dimensions with spectral domain optical coherence tomography (SD-OCT) and examined how ocular dimensions vary with alignment of the SD-OCT system in a mouse model of lens-induced myopia. Refractive error, corneal radius of curvature, and ocular dimensions were measured in C57BL/6J mice from P25 to P46. Mice received monocular lens treatment with either a -10D (n = 14) or -30D lens (n = 13) at P28 or had no lens treatment (n = 14). OCT images were taken at different eccentricities in the temporal, nasal, inferior, and superior quadrants of the eye. Axial length, vitreous chamber depth (VCD), and anterior chamber depth decreased with increasing eccentricity (P 0.05). Changes in corneal radius of curvature could predict the myopic shift observed with lens treatment. Findings suggest that there are significant differences in axial length measurements depending on the alignment of the OCT system. Thus, consistent alignment to the same region is important for accurate comparison of axial length in mouse eyes with experimental myopia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Emory University School of Medicine, 1365B Clifton Rd NE, Atlanta, GA, 30322, United States.
- Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Dr, Atlanta, GA, 30332, United States.
- Department of Ophthalmology, Emory University School of Medicine, 1365B Clifton Rd NE, Atlanta, GA, 30322, United States; Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 F…
Förderung
- RRD VA
- NEI NIH HHS
- U.S. Department of Veterans Affairs
- National Institutes of Health
- National Eye Institute
- Research to Prevent Blindness
Zitieren
APA
Lou, L., Hall, K. M., & Pardue, M. T. (2025). Examining murine eye length asymmetry with spectral domain optical coherence tomography. Experimental Eye Research. https://doi.org/10.1016/j.exer.2025.110648
Vancouver
Lou L, Hall KM, Pardue MT. Examining murine eye length asymmetry with spectral domain optical coherence tomography. Experimental Eye Research. 2025. doi:10.1016/j.exer.2025.110648
BibTeX
@article{Lou2025,
author = {Lou, Linjiang and Hall, Katelyn M and Pardue, Machelle T},
title = {Examining murine eye length asymmetry with spectral domain optical coherence tomography},
journal = {Experimental Eye Research},
year = {2025},
doi = {10.1016/j.exer.2025.110648}
}
EUVIMED