EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm

Olivia R Christiano iD, Sebastian Michelmann iD

Imaging Neuroscience · 08.05.2026 · 4

DOI: 10.1162/imag.a.1218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging Neuroscience, online erschienen am 08.05.2026. Verfasst von Olivia R Christiano und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Psychology, New York University, New York, NY, United States. Die Arbeit nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optically pumped magnetometers (OPMs) offer a promising advancement in noninvasive neuroimaging via magnetoencephalography (MEG), but establishing their reliability and comparability to existing methods remains an ongoing endeavor. Here, we evaluated OPM recordings by assessing their test-retest reliability and comparing them to functional magnetic resonance imaging (fMRI) and intracranial electroencephalography (iEEG) recordings. Data were collected from three independent participant groups during repeated viewings of a movie segment. In 7 canonical frequency bands (δ: 0.5–4 Hz, θ: 4–8 Hz, α: 8–12 Hz, β: 12–28 Hz, γ1: 28–46 Hz, γ2: 55–70 Hz, and HF: 64–116 Hz), as well as a broadband (BB: 0.5–116 Hz) signal, we quantified the signal consistency (1) within individuals, (2) across subjects, and (3) across modalities. OPM exhibited widespread reliability, particularly in lower frequency bands; spatial patterns resembled those of fMRI and iEEG in visual and auditory regions. Cross-modal analyses revealed robust correspondence between OPM and both fMRI and iEEG, including inverse correlations at low frequencies and positive correlations at higher frequencies in the OPM-fMRI comparison, consistent with known relationships between oscillatory power and BOLD responses. Comparisons of signal-to-noise (SNR) estimates further revealed that in some regions, the SNR of cross-modal alignment exceeded within-modality reliability, suggesting that bridging between modalities can sometimes enhance SNR by attenuating reliably shared noise. Our findings demonstrate that OPM consistently captures stimulus-driven neural dynamics that converge with established modalities.

Schlagwörter

Stichwörter der Autor:innen

MEGOPMcross-modal correlationfMRIiEEGintersubject correlationreliability

Autor:innen und Institutionen

  • Department of Psychology, New York University, New York, NY, United States.

ORCID-Profile: Olivia R Christiano, Sebastian Michelmann

Zitieren

APA

Christiano, O. R., & Michelmann, S. (2026). Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm. Imaging Neuroscience, 4. https://doi.org/10.1162/imag.a.1218

Vancouver

Christiano OR, Michelmann S. Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm. Imaging Neuroscience. 2026;4. doi:10.1162/imag.a.1218

BibTeX
@article{Christiano2026,
  author = {Christiano, Olivia R and Michelmann, Sebastian},
  title = {Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm},
  journal = {Imaging Neuroscience},
  year = {2026},
  volume = {4},
  doi = {10.1162/imag.a.1218}
}
Kostenlos starten →