EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Potential of 4 He OPM‐MEG for detecting interictal epileptic activity: A comparison with SQUID‐MEG

Denis Schwartz iD, Jean-Michel Badier, Tjerk P Gutteling, Sébastien Daligault, Etienne Labyt, Francesca Bonini, Julien Jung iD

Epilepsia Open · 2025-10 · 10 (5) · 1660-1672

DOI: 10.1002/epi4.70139 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Epilepsia Open, online erschienen am 12.09.2025. Verfasst von Denis Schwartz und 6 weiteren Autor:innen. Beteiligte Einrichtung: MEG Department, CERMEP-Imagerie du Vivant, Lyon, France. Hauptthemen laut MEDLINE: Magnetoencephalography, Epilepsy, Helium. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Agence Nationale de la Recherche, Excellence Initiative of Aix-Marseille University - A*MIDEX, Région Auvergne-Rhône-Alpes.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Conventional magnetoencephalography (MEG) based on superconducting quantum interference devices sensors (SQUIDs) is the only widely used MEG system in both clinical and research settings. However, it has limitations that hinder its widespread deployment. Optically pumped magnetometers (OPMs) offer several advantages over SQUIDs, particularly for epilepsy studies: lightweight and flexible, OPMs can be integrated into adaptable motion‐tolerant headsets, enabling recordings during seizures or natural head movements, and potentially enhancing the detection of interictal epileptiform discharges (IEDs). In the present study, we assess the capabilities of a 5‐sensor MEG system with helium OPMs ( 4 He‐OPMs) in detecting IEDs.

Methods

First, we compare the performance of SQUID‐MEG and 4 He‐OPM‐MEG in a group of 7 patients. Second, we perform combined intra‐cerebral (SEEG) 4 He‐OPM‐MEG and SQUID‐MEG recordings in a single patient to demonstrate the ability of both systems to detect IEDs originating from deep brain structures.

Results

The key finding is that both the SQUID‐MEG and the 4 He‐OPM‐MEG prototype, with a very limited number of sensors, successfully captured interictal epileptic activity in 5 of the 7 patients. This activity was clearly detectable and exhibited the characteristic morphology, with strikingly similar time courses between 4 He‐OPM‐MEG and SQUID‐MEG signals. Using combined SEEG and OPM‐MEG recordings, we obtained the first direct validation of the ability of 4 He OPM sensors to record epileptic activities originating from deep structures. Significance These results strongly support the clinical adoption of a lightweight, high‐sensitivity, whole‐head OPMs‐MEG system, offering new perspectives for epilepsy diagnostics and beyond, and enabling the democratization and spread of MEG in clinical and research settings. Plain language summary Magnetoencephalography is a noninvasive neuroimaging technique that has been shown to improve surgical outcomes in epileptic patients. However, its use remains limited due to several constraints, which could be overcome by a new generation of sensors: the optically pumped magnetometers (OPMs). Here, we validate the ability of OPM sensors to record epileptic brain activity in a regular clinical setup and thanks to simultaneous intracerebral recordings. These sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy, as well as for fundamental neuroscience.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnetoencephalographyEpilepsyHeliumHumansMaleFemaleAdultMiddle AgedYoung AdultElectroencephalographyBrain

Stichwörter der Autor:innen

epilepsyinterictal epileptic dischargesmagnetoencephalographyoptically pumped magnetometerssimultaneous recordingstereotactic‐EEG

Substanzen

Helium

Autor:innen und Institutionen

  • MEG Department, CERMEP-Imagerie du Vivant, Lyon, France.
  • CRNL, UMR_S 1028, INSERM, CNRS, Lyon University 1, HCL, Lyon, France.
  • INSERM, INS, Inst Neurosci Syst, Aix Marseille Univ, Marseille, France.
  • MAG4Health, Grenoble, France.
  • Epileptology and Cerebral Rythmology, APHM, Timone Hospital, Marseille, France.
  • Functional Neurology and Epileptology, HCL, Hospital Pierre Wertheimer, Lyon, France.

ORCID-Profile: Denis Schwartz, Julien Jung

Förderung

  • Agence Nationale de la Recherche
  • Excellence Initiative of Aix-Marseille University - A*MIDEX
  • Région Auvergne-Rhône-Alpes
  • Labex Cortex

Zitieren

APA

Schwartz, D., Badier, J. M., Gutteling, T. P., Daligault, S., Labyt, E., Bonini, F., & Jung, J. (2025). Potential of 4 He OPM‐MEG for detecting interictal epileptic activity: A comparison with SQUID‐MEG. Epilepsia Open, 10(5), 1660-1672. https://doi.org/10.1002/epi4.70139

Vancouver

Schwartz D, Badier JM, Gutteling TP, Daligault S, Labyt E, Bonini F, et al. Potential of 4 He OPM‐MEG for detecting interictal epileptic activity: A comparison with SQUID‐MEG. Epilepsia Open. 2025;10(5):1660-1672. doi:10.1002/epi4.70139

BibTeX
@article{Schwartz2025,
  author = {Schwartz, Denis and Badier, Jean-Michel and Gutteling, Tjerk P and Daligault, Sébastien and Labyt, Etienne and Bonini, Francesca and Jung, Julien},
  title = {Potential of 4 He OPM‐MEG for detecting interictal epileptic activity: A comparison with SQUID‐MEG},
  journal = {Epilepsia Open},
  year = {2025},
  volume = {10},
  number = {5},
  pages = {1660--1672},
  doi = {10.1002/epi4.70139}
}
Kostenlos starten →